You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/75050
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCurvo, E. A C-
dc.contributor.authorJonckheere, R.-
dc.contributor.authorGuedes, S.-
dc.contributor.authorIunes, P. J.-
dc.contributor.authorTello, C. A.-
dc.contributor.authorHadler, J. C.-
dc.contributor.authorUnterricker, S.-
dc.contributor.authorRatschbacher, L.-
dc.date.accessioned2014-05-27T11:28:49Z-
dc.date.accessioned2016-10-25T18:46:41Z-
dc.date.available2014-05-27T11:28:49Z-
dc.date.available2016-10-25T18:46:41Z-
dc.date.issued2013-04-02-
dc.identifierhttp://dx.doi.org/10.1016/j.radmeas.2013.03.002-
dc.identifier.citationRadiation Measurements.-
dc.identifier.issn1350-4487-
dc.identifier.urihttp://hdl.handle.net/11449/75050-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/75050-
dc.description.abstractThe two fundamental approaches to fission-track dating involve either an explicit determination of the thermal neutron fluence (φ-method) or a calibration against age standards (ζ-method). The neutron fluence measurements are carried out with metal-activation monitors or with uranium-fission monitors, co-irradiated with the samples. Uranium-fission monitors consist of either a thin mono-atomic) film, or a thick fission source (standard uranium glass) irradiated against a muscovite external track detector. In this work, different techniques for performing neutron-fluence measurements were compared: based on thin-film calibration, based on thick-source calibration, and based on gamma spectrometry of co-irradiated metal monitors (Au, Co). The results suggest that more experiments are needed to make all calibrations consistent, including new measurements of the length of etched induced tracks in mica. Also the standard glass calibration carried out with thin films should be confirmed with a greater number of calibrating irradiations. © 2013 Elsevier Ltd. All rights reserved.en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectFission-track-
dc.subjectMetal-activation monitors-
dc.subjectThermal neutron fluence-
dc.subjectUranium-fission monitors-
dc.titleA comparison between neutron-fluence measurements using metal-activation monitors and standard glasses calibrated via thin uranium-fission monitors and via ηq methoden
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.identifier.doi10.1016/j.radmeas.2013.03.002-
dc.identifier.wosWOS:000320975900006-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofRadiation Measurements-
dc.identifier.scopus2-s2.0-84875387846-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.