You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/75121
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlvarez, M.-
dc.contributor.authorPina, D. R.-
dc.contributor.authorDuarte, S. B.-
dc.contributor.authorSouza, R. T F-
dc.contributor.authorVelo, A. F.-
dc.contributor.authorTrindade, A. P.-
dc.contributor.authorMiranda, J. R A-
dc.date.accessioned2014-05-27T11:28:55Z-
dc.date.accessioned2016-10-25T18:47:26Z-
dc.date.available2014-05-27T11:28:55Z-
dc.date.available2016-10-25T18:47:26Z-
dc.date.issued2013-04-16-
dc.identifierhttp://dx.doi.org/10.1007/978-3-642-29305-4_213-
dc.identifier.citationIFMBE Proceedings, v. 39 IFMBE, p. 811-814.-
dc.identifier.issn1680-0737-
dc.identifier.urihttp://hdl.handle.net/11449/75121-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/75121-
dc.description.abstractThis paper presents a novel approach to the computed assessment of a mammographic phantom device. The approach shown here is fully automated and is based on the automatic selection of the region of interest, in the use of the discrete wavelet transform (DWT) and morphological operators to assess the quality of the American College of Radiology (ACR) mammographic phantom images. The algorithms developed here have succesfully scored 30 images obtained with different combinations of voltage applied to the tube and exposure and could notice the differences in the radiographs due to the different level of exposure to radiation. © 2013 Springer-Verlag.en
dc.format.extent811-814-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectaccreditation phantom-
dc.subjectcomputed image evaluation-
dc.subjectcomputed radiography-
dc.subjectmammography-
dc.subjectquality control-
dc.subjectAmerican college of radiologies-
dc.subjectAutomatic selection-
dc.subjectComputed radiography-
dc.subjectFully automated-
dc.subjectImage evaluation-
dc.subjectMammographic phantoms-
dc.subjectMorphological operator-
dc.subjectRegion of interest-
dc.subjectAccreditation-
dc.subjectBiomedical engineering-
dc.subjectDiscrete wavelet transforms-
dc.subjectPhysics-
dc.subjectQuality control-
dc.subjectRadiology-
dc.subjectMammography-
dc.titleWavelets in the computed evaluation of mammographic accreditation phantom imagesen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionCentro Brasileiro de Pesquisas Físicas (CBPF)-
dc.description.affiliationUniv. Estadual Paulista Júlio de Mesquita Filho - UNESP Departamento de Física e Biofísica Laboratório de Biomagnetimso, Botucatu-
dc.description.affiliationCentro Brasileiro de Pesquisas Física - CBPF, Rio de Janeiro-
dc.description.affiliationUnespUniv. Estadual Paulista Júlio de Mesquita Filho - UNESP Departamento de Física e Biofísica Laboratório de Biomagnetimso, Botucatu-
dc.identifier.doi10.1007/978-3-642-29305-4_213-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIFMBE Proceedings-
dc.identifier.scopus2-s2.0-84876016115-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.