Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/75546
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oliveira, Nilson T.C. | - |
dc.contributor.author | Guastaldi, Fernando P.S. | - |
dc.contributor.author | Perrotti, Vittoria | - |
dc.contributor.author | Hochuli-Vieira, Eduardo | - |
dc.contributor.author | Guastaldi, Antonio C. | - |
dc.contributor.author | Piattelli, Adriano | - |
dc.contributor.author | Iezzi, Giovanna | - |
dc.date.accessioned | 2014-05-27T11:29:35Z | - |
dc.date.accessioned | 2016-10-25T18:49:00Z | - |
dc.date.available | 2014-05-27T11:29:35Z | - |
dc.date.available | 2016-10-25T18:49:00Z | - |
dc.date.issued | 2013-06-01 | - |
dc.identifier | http://dx.doi.org/10.1111/j.1708-8208.2011.00354.x | - |
dc.identifier.citation | Clinical Implant Dentistry and Related Research, v. 15, n. 3, p. 427-437, 2013. | - |
dc.identifier.issn | 1523-0899 | - |
dc.identifier.issn | 1708-8208 | - |
dc.identifier.uri | http://hdl.handle.net/11449/75546 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/75546 | - |
dc.description.abstract | Purpose: In vivo bone response was assessed by removal torque, hystological and histometrical analysis on a recently developed biomedical Ti-15Mo alloy, after surface modification by laser beam irradiation, installed in the tibia of rabbits. Materials and Methods: A total of 32 wide cylindrical Ti-15Mo dental implants were obtained (10mm × 3.75mm). The implants were divided into two groups: 1) control samples (Machined surface - MS) and 2) implants with their surface modified by Laser beam-irradiation (Test samples - LS). Six implants of each surface were used for removal torque test and 10 of each surface for histological and histometrical analysis. The implants were placed in the tibial metaphyses of rabbits. Results: Average removal torque was 51.5Ncm to MS and >90Ncm to LS. Bone-to-implant-contact percentage was significantly higher for LS implants both in the cortical and marrow regions. Conclusions: The present study demonstrated that laser treated Ti-15Mo alloys are promising materials for biomedical application. © 2011 Wiley Periodicals, Inc. | en |
dc.format.extent | 427-437 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | Bone histomorphometry | - |
dc.subject | Laser beam surface modification | - |
dc.subject | Removal torque | - |
dc.subject | Ti-Mo alloys | - |
dc.subject | Titanium alloys | - |
dc.subject | Wettability | - |
dc.title | Biomedical Ti-Mo Alloys with Surface Machined and Modified by Laser Beam: Biomechanical, Histological, and Histometric Analysis in Rabbits | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | University of Chieti-Pescara | - |
dc.description.affiliation | Biomaterials Group, IQ Universidade Estadual Paulista UNESP, Araraquara, SP | - |
dc.description.affiliation | Department of Stomatology Dental School University of Chieti-Pescara, Chieti | - |
dc.description.affiliation | Departamento de Diagnóstico e Cirurgia Faculdade de Odontologia de Araraquara Universidade Estadual Paulista, UNESP, Araraquara, SP | - |
dc.description.affiliationUnesp | Biomaterials Group, IQ Universidade Estadual Paulista UNESP, Araraquara, SP | - |
dc.description.affiliationUnesp | Departamento de Diagnóstico e Cirurgia Faculdade de Odontologia de Araraquara Universidade Estadual Paulista, UNESP, Araraquara, SP | - |
dc.identifier.doi | 10.1111/j.1708-8208.2011.00354.x | - |
dc.identifier.wos | WOS:000319994700012 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Clinical Implant Dentistry and Related Research | - |
dc.identifier.scopus | 2-s2.0-84878784526 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.