You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/75670
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBronze-Uhle, E. S.-
dc.contributor.authorBatagin-Neto, A.-
dc.contributor.authorFernandes, D. M.-
dc.contributor.authorFratoddi, I.-
dc.contributor.authorRusso, M. V.-
dc.contributor.authorGraeff, Carlos Frederico de Oliveira-
dc.date.accessioned2014-05-27T11:29:41Z-
dc.date.accessioned2016-10-25T18:49:49Z-
dc.date.available2014-05-27T11:29:41Z-
dc.date.available2016-10-25T18:49:49Z-
dc.date.issued2013-06-17-
dc.identifierhttp://dx.doi.org/10.1063/1.4812186-
dc.identifier.citationApplied Physics Letters, v. 102, n. 24, 2013.-
dc.identifier.issn0003-6951-
dc.identifier.urihttp://hdl.handle.net/11449/75670-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/75670-
dc.description.abstractIn this work, the effect of gamma radiation on the optical properties of polymetallayne poly[1,1'-bis(ethynyl)-4,4'-biphenyl(bis-tributylphosphine)Pt(II) ] (Pt-DEBP) in chloroform solution is studied. The samples were irradiated at room temperature with doses from 0.01 Gy to 1 Gy using a 60Co gamma ray source. A new band at 420 nm is observed in the emission spectra, in superposition to the emission maximum at 398 nm, linearly dependent on dose. We propose to use the ratio of the emission amplitude bands as the dosimetric parameter. This method proved to be robust, accurate, and can be used as a dosimeter in medical applications. © 2013 AIP Publishing LLC.en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectChloroform solutions-
dc.subjectDosimetric parameter-
dc.subjectEmission maxima-
dc.subjectEmission spectrums-
dc.subjectGamma ray sources-
dc.subjectLow dose-
dc.subjectRadiation dosimeters-
dc.subjectRoom temperature-
dc.subjectEmission spectroscopy-
dc.subjectGamma rays-
dc.subjectIonizing radiation-
dc.subjectMedical applications-
dc.subjectPlatinum-
dc.titlePoly [1,1'-bis(ethynyl)-4,4'-biphenyl(bis-tributylphosphine)Pt(II)] solutions used as low dose ionizing radiation dosimeteren
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversity of Rome Sapienza-
dc.description.affiliationDepartment of Physics FC-UNESP, Av. Eng. Luiz Edmundo Carrijo Coube 14-01, 17033-360 Bauru-
dc.description.affiliationUNESP-Univ Estadual Paulista POSMAT-Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, Bauru, São Paulo-
dc.description.affiliationDepartment of Chemistry University of Rome Sapienza, P.le A. Moro 5, 00185 Rome-
dc.description.affiliationUnespDepartment of Physics FC-UNESP, Av. Eng. Luiz Edmundo Carrijo Coube 14-01, 17033-360 Bauru-
dc.description.affiliationUnespUNESP-Univ Estadual Paulista POSMAT-Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, Bauru, São Paulo-
dc.identifier.doi10.1063/1.4812186-
dc.identifier.wosWOS:000320962400038-
dc.rights.accessRightsAcesso restrito-
dc.identifier.file2-s2.0-84879804274.pdf-
dc.relation.ispartofApplied Physics Letters-
dc.identifier.scopus2-s2.0-84879804274-
dc.identifier.orcid0000-0003-0162-8273pt
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.