Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/75670
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorBronze-Uhle, E. S.-
dc.contributor.authorBatagin-Neto, A.-
dc.contributor.authorFernandes, D. M.-
dc.contributor.authorFratoddi, I.-
dc.contributor.authorRusso, M. V.-
dc.contributor.authorGraeff, Carlos Frederico de Oliveira-
dc.date.accessioned2014-05-27T11:29:41Z-
dc.date.accessioned2016-10-25T18:49:49Z-
dc.date.available2014-05-27T11:29:41Z-
dc.date.available2016-10-25T18:49:49Z-
dc.date.issued2013-06-17-
dc.identifierhttp://dx.doi.org/10.1063/1.4812186-
dc.identifier.citationApplied Physics Letters, v. 102, n. 24, 2013.-
dc.identifier.issn0003-6951-
dc.identifier.urihttp://hdl.handle.net/11449/75670-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/75670-
dc.description.abstractIn this work, the effect of gamma radiation on the optical properties of polymetallayne poly[1,1'-bis(ethynyl)-4,4'-biphenyl(bis-tributylphosphine)Pt(II) ] (Pt-DEBP) in chloroform solution is studied. The samples were irradiated at room temperature with doses from 0.01 Gy to 1 Gy using a 60Co gamma ray source. A new band at 420 nm is observed in the emission spectra, in superposition to the emission maximum at 398 nm, linearly dependent on dose. We propose to use the ratio of the emission amplitude bands as the dosimetric parameter. This method proved to be robust, accurate, and can be used as a dosimeter in medical applications. © 2013 AIP Publishing LLC.en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectChloroform solutions-
dc.subjectDosimetric parameter-
dc.subjectEmission maxima-
dc.subjectEmission spectrums-
dc.subjectGamma ray sources-
dc.subjectLow dose-
dc.subjectRadiation dosimeters-
dc.subjectRoom temperature-
dc.subjectEmission spectroscopy-
dc.subjectGamma rays-
dc.subjectIonizing radiation-
dc.subjectMedical applications-
dc.subjectPlatinum-
dc.titlePoly [1,1'-bis(ethynyl)-4,4'-biphenyl(bis-tributylphosphine)Pt(II)] solutions used as low dose ionizing radiation dosimeteren
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversity of Rome Sapienza-
dc.description.affiliationDepartment of Physics FC-UNESP, Av. Eng. Luiz Edmundo Carrijo Coube 14-01, 17033-360 Bauru-
dc.description.affiliationUNESP-Univ Estadual Paulista POSMAT-Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, Bauru, São Paulo-
dc.description.affiliationDepartment of Chemistry University of Rome Sapienza, P.le A. Moro 5, 00185 Rome-
dc.description.affiliationUnespDepartment of Physics FC-UNESP, Av. Eng. Luiz Edmundo Carrijo Coube 14-01, 17033-360 Bauru-
dc.description.affiliationUnespUNESP-Univ Estadual Paulista POSMAT-Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, Bauru, São Paulo-
dc.identifier.doi10.1063/1.4812186-
dc.identifier.wosWOS:000320962400038-
dc.rights.accessRightsAcesso restrito-
dc.identifier.file2-s2.0-84879804274.pdf-
dc.relation.ispartofApplied Physics Letters-
dc.identifier.scopus2-s2.0-84879804274-
dc.identifier.orcid0000-0003-0162-8273pt
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.