You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/75729
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPott Marinho Ballottin, Daniela-
dc.contributor.authorLataro Paim, Leonardo-
dc.contributor.authorRamos Stradiotto, Nelson-
dc.date.accessioned2014-05-27T11:29:47Z-
dc.date.accessioned2016-10-25T18:50:13Z-
dc.date.available2014-05-27T11:29:47Z-
dc.date.available2016-10-25T18:50:13Z-
dc.date.issued2013-07-01-
dc.identifierhttp://dx.doi.org/10.1002/elan.201300090-
dc.identifier.citationElectroanalysis, v. 25, n. 7, p. 1751-1755, 2013.-
dc.identifier.issn1040-0397-
dc.identifier.issn1521-4109-
dc.identifier.urihttp://hdl.handle.net/11449/75729-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/75729-
dc.description.abstractA glassy carbon electrode chemically modified with nickel oxyhydroxide from a nickel hexacyanoferrate (NiHCF) film was used to determine glycerol in biodiesel by cyclic voltammetry. The modified electrode exhibited a linear response to glycerol concentration in the range from 0.05 to 0.35mmol L-1, and a detection limit of 0.030mmol L-1. The glycerol concentration found in the biodiesel sample was 0.156mmol L-1. The method developed in this study showed a recovery of (100.3±5.0)%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.en
dc.format.extent1751-1755-
dc.language.isoeng-
dc.sourceScopus-
dc.subjectBiodiesel-
dc.subjectCyclic voltammetry-
dc.subjectGlycerol-
dc.subjectNickel oxy/hydroxide electrode-
dc.titleDetermination of Glycerol in Biodiesel Using a Nickel(II) Oxyhydroxide Chemically Modified Electrode by Cyclic Voltammetryen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationAnalytical Chemistry Department Institute of Chemistry Universidade Estadual Paulista (UNESP), 55 Francisco Degni st, 14800-900, Araraquara, SP-
dc.description.affiliationUnespAnalytical Chemistry Department Institute of Chemistry Universidade Estadual Paulista (UNESP), 55 Francisco Degni st, 14800-900, Araraquara, SP-
dc.identifier.doi10.1002/elan.201300090-
dc.identifier.wosWOS:000327662000026-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectroanalysis-
dc.identifier.scopus2-s2.0-84880340551-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.