Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/76288
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pourakbari Kasmaei, M. | - |
dc.contributor.author | Rider, M. J. | - |
dc.contributor.author | Mantovani, J. R S | - |
dc.date.accessioned | 2014-05-27T11:30:11Z | - |
dc.date.accessioned | 2016-10-25T18:52:43Z | - |
dc.date.available | 2014-05-27T11:30:11Z | - |
dc.date.available | 2016-10-25T18:52:43Z | - |
dc.date.issued | 2013-08-19 | - |
dc.identifier | http://dx.doi.org/10.1109/EEEIC.2013.6549538 | - |
dc.identifier.citation | 12th International Conference on Environment and Electrical Engineering, EEEIC 2013, p. 335-340. | - |
dc.identifier.uri | http://hdl.handle.net/11449/76288 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/76288 | - |
dc.description.abstract | This paper proposes a straightforward compromising method to determine the output power of all committed units during the scheduling time horizon. Unlike the conventional methods that work based on a constant pollution control cost (CPCC), this method works based on the system topology such as demand, minimum cost and minimum output emission of the system. In order to have a meaningful compromise between costs and emission in economic and emission dispatch (EED) problem, a flexible pollution control cost (FPCC) is proposed. Also a dynamic economic emission dispatch (DEED) approach is considered where the ramping constraints couple the scheduling hours; the inclusion of valve-point effect makes the DEED modeling more practical. The validity and effectiveness of the unproblematic FPCC approach is verified through an IEEE 30-bus test system with 6 unit for the 6-hour scheduling horizon. © 2013 IEEE. | en |
dc.format.extent | 335-340 | - |
dc.language.iso | eng | - |
dc.source | Scopus | - |
dc.subject | dynamic dispatch | - |
dc.subject | economic and emission dispatch | - |
dc.subject | ramp rate limit | - |
dc.subject | valve-point effect | - |
dc.subject | Conventional methods | - |
dc.subject | Dynamic dispatch | - |
dc.subject | Dynamic economic emission dispatch (DEED) | - |
dc.subject | Economic and emission dispatch | - |
dc.subject | Ramp rate limits | - |
dc.subject | Ramping constraint | - |
dc.subject | System topology | - |
dc.subject | Valve point effects | - |
dc.subject | Electrical engineering | - |
dc.subject | Pollution induced corrosion | - |
dc.subject | Scheduling | - |
dc.subject | Costs | - |
dc.title | A novel straightforward compromising method for dynamic economic and emission dispatch considering valve-point effect | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Department of Electrical and Electronic Engineering UNESP, Ilha Solteira | - |
dc.description.affiliationUnesp | Department of Electrical and Electronic Engineering UNESP, Ilha Solteira | - |
dc.identifier.doi | 10.1109/EEEIC.2013.6549538 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | 12th International Conference on Environment and Electrical Engineering, EEEIC 2013 | - |
dc.identifier.scopus | 2-s2.0-84881441253 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.