dc.description.abstractDemand response has gained increasing importance in the context of competitive electricity markets and smart grid environments. In addition to the importance that has been given to the development of business models for integrating demand response, several methods have been developed to evaluate the consumers' performance after the participation in a demand response event. The present paper uses those performance evaluation methods, namely customer baseline load calculation methods, to determine the expected consumption in each period of the consumer historic data. In the cases in which there is a certain difference between the actual consumption and the estimated consumption, the consumer is identified as a potential cause of non-technical losses. A case study demonstrates the application of the proposed method to real consumption data. © 2013 IEEE.en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectCustomer baseline load-
dc.subjectdemand response-
dc.subjectnontechnical losses-
dc.subjectperformance evaluation methods-
dc.subjectsmart grid-
dc.subjectCustomer baseline loads-
dc.subjectDemand response-
dc.subjectEvaluation methods-
dc.subjectNon-technical loss-
dc.subjectSmart grid-
dc.subjectSmart power grids-
dc.titleUsing baseline methods to identify non-technical losses in the context of smart gridsen
dc.typeoutro-
dc.contributor.institutionPolytechnic Institute of Porto-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationGECAD Knowledge Engineering and Decision Support Research Center IPP Polytechnic Institute of Porto, Porto-
dc.description.affiliationDepartment of Electrical Engineering UNESP Univ Estadual Paulista, Bauru-
dc.description.affiliationUnespDepartment of Electrical Engineering UNESP Univ Estadual Paulista, Bauru-
dc.identifier.doi10.1109/ISGT-LA.2013.6554495-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartof2013 IEEE PES Conference on Innovative Smart Grid Technologies, ISGT LA 2013-
dc.identifier.scopus2-s2.0-84882390963-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.