You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/76355
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMatelli, José Alexandre-
dc.contributor.authorBazzo, Edson-
dc.date.accessioned2014-05-27T11:30:30Z-
dc.date.accessioned2016-10-25T18:53:02Z-
dc.date.available2014-05-27T11:30:30Z-
dc.date.available2016-10-25T18:53:02Z-
dc.date.issued2013-08-29-
dc.identifierhttp://dx.doi.org/10.1016/j.ijrefrig.2013.06.011-
dc.identifier.citationInternational Journal of Refrigeration.-
dc.identifier.issn0140-7007-
dc.identifier.urihttp://hdl.handle.net/11449/76355-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/76355-
dc.description.abstractCombined Refrigeration and Power (CRP) plants generate power and refrigerate a thermal load simultaneously from the same fuel. The overall efficiency is a parameter based on the first law generally used to quantify the fuel saving, in the sense that a plant that has greater overall efficiency saves more fuel than others to generate the same useful energy. However, the literature shows that the overall efficiency and other parameters of performance are defined in several different ways. This heterogeneity is not desirable when considering a coherent and universally accepted parameter of performance based on the first law. In this work, some parameters found in the literature are critically analyzed in order to indicate the most proper one. The indicated parameter is then formally analyzed in order to verify its mathematical consistency. The primary energy rate is considered the most well-suited parameter based on the first law to characterize the performance of a CRP plant. © 2013 Elsevier Ltd and IIR.en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectCogeneration-
dc.subjectEfficiency-
dc.subjectPrimary energy-
dc.titleOn the parameters of performance of combined refrigeration and power plantsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)-
dc.identifier.doi10.1016/j.ijrefrig.2013.06.011-
dc.identifier.wosWOS:000330814300014-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Journal of Refrigeration-
dc.identifier.scopus2-s2.0-84882791910-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.