You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/76367
Full metadata record
DC FieldValueLanguage
dc.contributor.authorThiesen, Guilherme-
dc.contributor.authorShimizu, Roberto Hideo-
dc.contributor.authordo Valle, Caio Vinicius Martins-
dc.contributor.authordo Valle-Corotti, Karyna Martins-
dc.contributor.authorPereira, Jefferson Ricardo-
dc.contributor.authorConti, Paulo Cesar Rodrigues-
dc.date.accessioned2014-05-27T11:30:30Z-
dc.date.accessioned2016-10-25T18:53:03Z-
dc.date.available2014-05-27T11:30:30Z-
dc.date.available2016-10-25T18:53:03Z-
dc.date.issued2013-08-30-
dc.identifierhttp://dx.doi.org/10.1590/S2176-94512013000200007-
dc.identifier.citationDental Press Journal of Orthodontics, v. 18, n. 2, 2013.-
dc.identifier.issn2176-9451-
dc.identifier.issn2177-6709-
dc.identifier.urihttp://hdl.handle.net/11449/76367-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/76367-
dc.description.abstractObjective: To determine the mechanical characteristics of teardrop loop with and without helix fabricated using different metal alloy compositions (stainless steel and beta-titanium), submitted to different intensities of bends preactivation (0° and 40°), and with different cross-sectional dimension of the wire used to build these loops (0.017 x 0.025-in and 0.019 x 0.025-in). Methods: Eighty loops used to close spaces were submitted to mechanical tests. The magnitudes of horizontal force, the moment/force ratio, and the load/deflection ratio produced by the specimens were quantified. Loops were submitted to a total activation of 5.0 mm and the values were registered for each 1.0 mm of activation. For statistic data analysis, a analysis of variance was performed and a Tukey's Multiple Comparison test was used as supplement, considering a 5% level of significance. Results: In general, teardrop loops with helix produced lower magnitudes of horizontal force and load/deflection ratio, and higher moment/force ratio than teardrop loops without helix. Among all analyzed variables, metal alloy composition presented greater influence in the horizontal force and in the load/deflection ratio. The moment/force ratio showed to be more influenced by the preactivation of loops for space closure. © 2013 Dental Press Journal of Orthodontics.en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectBiomechanics-
dc.subjectOrthodontic space closure-
dc.subjectOrthodontics-
dc.subjectTooth extraction-
dc.titleDetermination of the force systems produced by different configurations of tear drop orthodontic loopsen
dc.typeoutro-
dc.contributor.institutionUNISUL-SC and UNIASSELVI-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.description.affiliationPUCRS Graduation and Post-graduation course in Orthodontics UNISUL-SC and UNIASSELVI-
dc.description.affiliationUNESP-Araraquara Tuiuti University-
dc.description.affiliationFOB-USP Leonardo da Vinci University-
dc.description.affiliationFOB-USP UNICID-
dc.description.affiliationFOB-USP UNISUL-SC-
dc.description.affiliationProsthesis FOB-USP-
dc.description.affiliationUnespUNESP-Araraquara Tuiuti University-
dc.identifier.doi10.1590/S2176-94512013000200007-
dc.identifier.scieloS2176-94512013000200007-
dc.rights.accessRightsAcesso aberto-
dc.identifier.file2-s2.0-84882932748.pdf-
dc.relation.ispartofDental Press Journal of Orthodontics-
dc.identifier.scopus2-s2.0-84882932748-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.