You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/76421
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCastro, A.-
dc.contributor.authorLaRoche, D. P.-
dc.contributor.authorFraga, C. H W-
dc.contributor.authorGonçalves, M.-
dc.date.accessioned2014-05-27T11:30:33Z-
dc.date.accessioned2016-10-25T18:53:11Z-
dc.date.available2014-05-27T11:30:33Z-
dc.date.available2016-10-25T18:53:11Z-
dc.date.issued2013-09-01-
dc.identifierhttp://dx.doi.org/10.1016/j.scispo.2012.11.002-
dc.identifier.citationScience and Sports, v. 28, n. 4, 2013.-
dc.identifier.issn0765-1597-
dc.identifier.issn1778-4131-
dc.identifier.urihttp://hdl.handle.net/11449/76421-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/76421-
dc.description.abstractObjective: To analyze the effect of running intensity on stride length (SL), stride frequency (SF), stride time (ST) and the electromyographic signal of the rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM), tibialis anterior (TA), biceps femoris (BF) and gastrocnemius lateralis (GL) muscles. Methods: Nine well-trained runners performed an incremental protocol with an initial velocity of 10km.h-1, and increments of 1km.h-1 every 3minutes until exhaustion. The electromyographic activity, SL, SF, ST, inter-stride coefficient of variation, and association between kinematic and electromyographic parameters were calculated at 60%, 80% and 100% of maximum running velocity. Results: SL, SF and electromyographic activity of the RF, VM, VL and GL increased and the ST decreased with increased running speed. Electromyographic variability of VL and VM was higher than GL, and variability was lower in TA than all other muscles. The inter-stride variability of muscle activation was associated with kinematic parameters, and their variability, differently as running speed increased. Conclusion: The incremental protocol increased electromyographic activity differently among lower limb muscles; increased SF and SL, and decreased ST, without changing the variability of these variables. Muscle activation variability was correlated with kinematic parameters, but the relationships among these measures varied with running intensity. © 2013 .en
dc.language.isoeng-
dc.sourceScopus-
dc.subjectElectromyography-
dc.subjectKinematics-
dc.subjectPerformance-
dc.subjectRunning speed-
dc.subjectadult-
dc.subjectelectromyography-
dc.subjectexercise intensity-
dc.subjectgait-
dc.subjectgastrocnemius muscle-
dc.subjecthuman-
dc.subjectkinematics-
dc.subjectmale-
dc.subjectmuscle contraction-
dc.subjectpriority journal-
dc.subjectrectus femoris muscle-
dc.subjectrunning-
dc.subjectstride frequency-
dc.subjectstride length-
dc.subjectstride time-
dc.subjecttibialis anterior muscle-
dc.subjectvastus lateralis muscle-
dc.subjectvastus medialis muscle-
dc.subjectvelocity-
dc.titleRelationship between running intensity, muscle activation, and stride kinematics during an incremental protocolen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversity of New Hampshire-
dc.description.affiliationBiomechanics laboratory Department of physical education Biosciences institute, São Paulo State university, avenue 24-A, No. 1515, Bela Vista, CEP 13506-900, Rio Claro, São Paulo-
dc.description.affiliationDepartment of kinesiology University of New Hampshire, 124, Main-Street, Durham, NH 03824-
dc.description.affiliationUnespBiomechanics laboratory Department of physical education Biosciences institute, São Paulo State university, avenue 24-A, No. 1515, Bela Vista, CEP 13506-900, Rio Claro, São Paulo-
dc.identifier.doi10.1016/j.scispo.2012.11.002-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofScience and Sports-
dc.identifier.scopus2-s2.0-84883599252-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.