Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/76748
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Silva, Acacio | - |
dc.contributor.author | Piantini, Alexandre | - |
dc.date.accessioned | 2014-05-27T11:30:49Z | - |
dc.date.accessioned | 2016-10-25T18:54:45Z | - |
dc.date.available | 2014-05-27T11:30:49Z | - |
dc.date.available | 2016-10-25T18:54:45Z | - |
dc.date.issued | 2013-10-01 | - |
dc.identifier | http://dx.doi.org/10.1109/TLA.2013.6601745 | - |
dc.identifier.citation | IEEE Latin America Transactions, v. 11, n. 4, p. 1022-1028, 2013. | - |
dc.identifier.issn | 1548-0992 | - |
dc.identifier.uri | http://hdl.handle.net/11449/76748 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/76748 | - |
dc.description.abstract | Models of different degrees of complexity are found in the literature for the estimation of lightning striking distances and attractive radius of objects and structures. However, besides the oversimplifications of the physical nature of the lightning discharge on which most of them are based, till recently the tridimensional structure configuration could not be considered. This is an important limitation, as edges and other details of the object affect the electric field and, consequently, the upward leader initiation. Within this context, the Self-consistent leader initiation and propagation model (SLIM) proposed by Becerra and Cooray is state-of-the-art leader inception and propagation leader model based on the physics of leader discharges which enables the tridimensional geometry of the structure to be taken into account. In this paper, the model is used for estimating the striking distance and attractive radius of power transmission lines. The results are compared with those obtained from the electrogeometric and Eriksson's models. © 2003-2012 IEEE. | en |
dc.format.extent | 1022-1028 | - |
dc.language.iso | por | - |
dc.source | Scopus | - |
dc.subject | electrogeometric model | - |
dc.subject | lightning attachment | - |
dc.subject | lightning interception model | - |
dc.subject | power transmission lines | - |
dc.subject | striking distance | - |
dc.title | Analysis of the lightning attractive radius of power transmission lines through the use of a physically-oriented model | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade Federal do Paraná (UFPR) | - |
dc.description.affiliation | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Universidade Federal Do Paraná | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista (UNESP) | - |
dc.identifier.doi | 10.1109/TLA.2013.6601745 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | IEEE Latin America Transactions | - |
dc.identifier.scopus | 2-s2.0-84884640656 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.