Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/87183
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Marafão, Fernando Pinhabel [UNESP] | - |
dc.contributor.author | Arbex, Cristiano José Nicolau | - |
dc.date.accessioned | 2014-06-11T19:22:34Z | - |
dc.date.accessioned | 2016-10-25T18:57:06Z | - |
dc.date.available | 2014-06-11T19:22:34Z | - |
dc.date.available | 2016-10-25T18:57:06Z | - |
dc.date.issued | 2011-08-19 | - |
dc.identifier.citation | ARBEX, Cristiano José Nicolau. Aplicação da teoria de potência conservativa para compensação de distúrbios de corrente. 2011. 73 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Engenharia, 2011. | - |
dc.identifier.uri | http://hdl.handle.net/11449/87183 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/87183 | - |
dc.description.abstract | Este trabalho apresenta um estudo de aplicação da Teoria de Potência Conservativa (CPT) na geração da referência para um filtro ativo de potência paralelo (FAP), a fim de promover a compensação de distúrbios de corrente em um sistema elétrico trifásico a três fios. Apresenta, também, um resumo de algumas das principais teorias de potência utilizadas na análise de sistemas elétricos com formas de onda não senoidais e desequilibradas, especialmente aquelas úteis para o controle de filtros ativos. Atenção especial foi dada para a teoria CPT que, além de ser uma proposta recente, permite selecionar o distúrbio a ser compensado pelo filtro ativo paralelo, bastando definir sua referência a partir das parcelas de corrente da CPT. Neste trabalho também foi proposta uma metodologia de projeto para filtros ativos paralelo, a qual é baseada na análise da carga através da CPT e em função da compensação seletiva de distúrbios. Dessa forma é possível estudar a viabilidade econômica de um dado filtro ativo paralelo escolhendo a parcela de corrente mais adequada a ser compensada, obviamente, dentro de uma determinada configuração de carga. Outro ponto destacado no trabalho foi a introdução de uma nova definição de fator de potência, proposta pela CPT e que, além de reativos, também considera os efeitos dos desequilíbrios e das distorções no sistema elétrico. Com base nesta nova definição, percebe-se a necessidade de uma revisão dos valores de referência definidos pelas normas atuais para o fator de potência. A validação dos estudos e do uso da CPT no controle do filtro ativo paralelo foi feita através de simulações computacionais no software PSIM | pt |
dc.description.abstract | This work presents an application study of the Conservative Power Theory (CPT) in the generation of control reference for a Parallel Active Power Filter (PAF), in order to compensate current disturbances in a Three-phase three-wite electrical power system. Some of the most important power teories find in literature have also been summarized, especially those related to active filter controlling techniques. Special attention was given for the CPT, since is a recent proposal and it allows the selection of the disturbance to be compensated through the definition of different control references using different CPT current parcels. An alternative methodology has also been proposed tot the design of the parallel active power filter, which is based on the analysis of the load by means of the CPT current decomposition and according to a previously defined selective compensating strategy. Therefore, it is possible to analyze the economic viability of the active power filter implementation if choosing the most important disturbance to be compensated, obvioulsly assuming a specific load configuration. Other important contribution was the discussion of a new power factor definition (proposed by the CPT), which considers not only the load reactive behavior, but also the effects of current unbalances and distortions on the efficiency of the power circuit. Based on this new definition, we observe the necessity of revising the normalized referential values in order to ensure a proper accountability or revenue metering methodology. Finally, the theoretical studies and the CPT application for controlling a parallel active filter were validated by means of computational simulations using PSIM software | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
dc.format.extent | 73 f. : il. | - |
dc.language.iso | por | - |
dc.publisher | Universidade Estadual Paulista (UNESP) | - |
dc.source | Aleph | - |
dc.subject | Potencia reativa (Engenharia eletrica) | pt |
dc.subject | Fator de potencia | pt |
dc.subject | Conservative Power Theory (CPT) | en |
dc.title | Aplicação da teoria de potência conservativa para compensação de distúrbios de corrente | pt |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | arbex_cjn_me_bauru.pdf | - |
dc.identifier.aleph | 000675708 | - |
dc.identifier.capes | 33004056087P2 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.