Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/87190
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Martins, André Christovão Pio [UNESP] | - |
dc.contributor.author | Martins, Luís Fabiano Barone | - |
dc.date.accessioned | 2014-06-11T19:22:34Z | - |
dc.date.accessioned | 2016-10-25T18:57:06Z | - |
dc.date.available | 2014-06-11T19:22:34Z | - |
dc.date.available | 2016-10-25T18:57:06Z | - |
dc.date.issued | 2011-02-23 | - |
dc.identifier.citation | MARTINS, Luís Fabiano Barone. Método do look ahead modificado para estudos de colapso de tensão. 2011. 117 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Engenharia, 2011. | - |
dc.identifier.uri | http://hdl.handle.net/11449/87190 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/87190 | - |
dc.description.abstract | Neste trabalho foi feita uma análise comparativa entre diferentes escolhas dos pontos utilizados pelo método look ahead na estimação do ponto de máximo carregamento de um sistema elétrico de potência. O Fluxo de Cargo Continuado é utilizado na geração dos pontos de operação utilizados pelo método look ahead e para servir como referência na comparação entre os resultados previstos e o ponto de máximo carregamento real. Uma vez que a exatidão dessa estimativa é fortemente afetada pela escolha desses pontos, o FCC é modificado para fornecer pontos mais adequados para o bom funcionamento do método look ahead. A metodologia proposta é aplicada ao sistema IEEE de 300 barras, os resultados obtidos mostram o seu bom funcionamento | pt |
dc.description.abstract | Here we did a comparative analysis between different choices of the points used by the look ahead method for estimating maximum loading point of a power system. The Continued Power Flow (CPF) is used in the generation of operating points used by the look ahead method and to serve as a reference in comparison between the predicted results and the real maximum loading point. Since the accurancy of this estimative is strongly affected by choicen of these points, the CPF is modified to provide the most appropriate for the proper functioning of the method look ahead. The proposed methodology system is applied to IEEE 300 buses, the results have shown its good functioning | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
dc.format.extent | 117 f. : il. | - |
dc.language.iso | por | - |
dc.publisher | Universidade Estadual Paulista (UNESP) | - |
dc.source | Aleph | - |
dc.subject | Sistemas de energia eletrica | pt |
dc.subject | Engenharia eletrica | pt |
dc.subject | Continued Power Flow | en |
dc.subject | Look ahead | en |
dc.subject | Voltage collapse | en |
dc.subject | Voltage stability margin | en |
dc.title | Método do look ahead modificado para estudos de colapso de tensão | pt |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | martins_lfb_me_bauru.pdf | - |
dc.identifier.aleph | 000641488 | - |
dc.identifier.capes | 33004056087P2 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.