You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/88341
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorBatistuti, José Paschoal [UNESP]-
dc.contributor.authorSantos, Flávia Regina dos-
dc.date.accessioned2014-06-11T19:23:25Z-
dc.date.accessioned2016-10-25T18:59:37Z-
dc.date.available2014-06-11T19:23:25Z-
dc.date.available2016-10-25T18:59:37Z-
dc.date.issued2012-12-06-
dc.identifier.citationSANTOS, Flávia Regina dos. Método de Lowry: validação e estimativa do cálculo da incerteza. 2012. 63 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Ciências Farmacêuticas, 2012.-
dc.identifier.urihttp://hdl.handle.net/11449/88341-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/88341-
dc.description.abstractAs proteínas são de fundamental importância nos processos biológicos atuando como enzimas, hormônios, neurotransmissores, transportadores através de membranas entre outros, pois são essenciais sob os aspectos da estrutura e função celular. Tem se tornado cada vez mais relevante o estudo de metodologias para determinar proteínas em várias áreas como em tecnologia e ciência de alimentos, laboratórios de análises clínicas, nutrição animal e humana. Antes de iniciar qualquer tipo de análise de proteínas, o método utilizado deve ser validado, pois a validação de métodos é um aspecto vital da garantia da qualidade analítica. A validação é um processo dinâmico e constante que começa na fase de seleção, desenvolvimento e otimização do método e na qualificação dos instrumentos, materiais e analistas continuando na fase de experimentos. Um processo de validação bem definido e documentado oferece as agências reguladoras evidências de que o método é adequado. As características investigadas no processo de validação a fim de demonstrar o desempenho do método são: Linearidade, Faixa linear de trabalho, Limite de detecção, Limite de quantificação, Precisão, Exatidão, Precisão intermediária, Robustez, Especificidade, Incerteza de medição e Recuperação. Os métodos mais utilizados para quantificar proteínas são Biureto, Bradford, BCA, Kjeldahl e de Lowry, sendo o método de Lowry o mais utilizado. Devido aos interferentes e a incerteza do método em relação aos parâmetros analisados, este trabalho teve o propósito de realizar a validação do método de Lowry modificado quanto aos parâmetros preconizados pela NATA. A proteína utilizada em todo o experimento foi a albumina bovina sérica – BSA e a metodologia foi a original com algumas modificações...pt
dc.description.abstractThe proteins are of fundamental importance in biological processes acting as enzymes, hormones, neurotransmitters, transporters across membranes among others, as they are essential aspects in the structure and cellular function. It has become increasingly relevant the study of methodologies for determining proteins in various areas such as technology and food science, clinical laboratories, animal and human nutrition. Before starting any type of protein analysis, the method used must be validated because the method validation is a vital aspect of analytical quality assurance. Validation is a constant and dynamic process that begins at the stage of selection, development and optimization of the method and the qualification of tools, materials, analysts and continuing in the experimental phase. A validation process well defined and documented regulatory agencies provides evidence that the method is appropriate. The characteristics investigated in the validation process to demonstrate the performance of the method are: linearity, linear working range, limit of detection, limit of quantification, precision, accuracy, precision intermediate, robustness, specificity, uncertainty of measurement and recovery. The methods used to quantify proteins are Biuret, Bradford, BCA, Kjeldahl, and Lowry, the method of Lowry the most used. Due to interferences and uncertainty regarding the method parameters, this study aimed to perform the validation Lowry´s method modified the parameters recommended by NATA. The protein used throughout the experiment was to bovine serum albumin - BSA and was the original method with some modifications. Despite the existence of many modern techniques, the spectrophotometric method has been shown to be effective, in addition to lower cost and easy handling. The method was developed and validateden
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.description.sponsorshipUniversidade Estadual Paulista (UNESP)-
dc.format.extent63 f. : grafs.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectAnálise espectralpt
dc.subjectProteinas - Analisept
dc.subjectEspectrofotômetropt
dc.subjectAlbuminapt
dc.subjectProgramas de computador - Validaçãopt
dc.subjectProteins - Analysispt
dc.titleMétodo de Lowry: validação e estimativa do cálculo da incertezapt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filesantos_fr_me_arafcf.pdf-
dc.identifier.aleph000706637-
dc.identifier.capes33004030055P6-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.