You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/8839
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUstra, Andrea Teixeira-
dc.contributor.authorElis, Vagner Roberto-
dc.contributor.authorMondelli, Giulliana-
dc.contributor.authorZuquette, Lazaro Valentin-
dc.contributor.authorGiacheti, Heraldo Luiz-
dc.date.accessioned2014-05-20T13:27:07Z-
dc.date.accessioned2016-10-25T16:47:06Z-
dc.date.available2014-05-20T13:27:07Z-
dc.date.available2016-10-25T16:47:06Z-
dc.date.issued2012-06-01-
dc.identifierhttp://dx.doi.org/10.1007/s12665-011-1284-5-
dc.identifier.citationEnvironmental Earth Sciences. New York: Springer, v. 66, n. 3, p. 763-772, 2012.-
dc.identifier.issn1866-6280-
dc.identifier.urihttp://hdl.handle.net/11449/8839-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/8839-
dc.description.abstractA contaminated site from a downstream municipal solid waste disposal site in Brazil was investigated by using a 3D resistivity and induced polarization (IP) imaging technique. This investigation purpose was to detect and delineate contamination plume produced by wastes. The area was selected based on previous geophysical investigations, and chemical analyses carried out in the site, indicating the presence of a contamination plume in the area. Resistivity model has successfully imaged waste presence (rho < 20 Omega m), water table depth, and groundwater flow direction. A conductive anomaly (rho < 20 Omega m) outside wastes placement was interpreted as a contamination plume. Chargeability model was also able to imaging waste presence (m > 31 mV/V), water table depth, and groundwater flow direction. A higher chargeability zone (m > 31 mV/V) outside wastes placement and following conductive anomaly was interpreted as a contamination plume. Normalized chargeability (MN = m/rho) confirmed polarizable zone, which could be an effect of a salinity increase (contamination plume), and the clay presence in the environment.en
dc.format.extent763-772-
dc.language.isoeng-
dc.publisherSpringer-
dc.sourceWeb of Science-
dc.subject3D inversionen
dc.subjectInduced polarizationen
dc.subjectResistivityen
dc.subjectChargeabilityen
dc.subjectNormalized chargeabilityen
dc.subjectWaste disposal siteen
dc.subjectContamination plumeen
dc.titleCase study: a 3D resistivity and induced polarization imaging from downstream a waste disposal site in Brazilen
dc.typeoutro-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionCtr Tecnol Ambientais & Energet CETAE-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv São Paulo, Inst Astron Geophys & Atmospher Sci, Secretaria Geofis, BR-05508090 São Paulo, Brazil-
dc.description.affiliationCtr Tecnol Ambientais & Energet CETAE, Inst Pesquisas Tecnol Estado São Paulo, BR-05508901 São Paulo, Brazil-
dc.description.affiliationUniv São Paulo, Dept Geotech Engn, BR-13566590 São Carlos, SP, Brazil-
dc.description.affiliationUniv Estadual Paulista, Dept Civil Engn, BR-17033360 Bauru, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Dept Civil Engn, BR-17033360 Bauru, SP, Brazil-
dc.identifier.doi10.1007/s12665-011-1284-5-
dc.identifier.wosWOS:000304624100007-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofEnvironmental Earth Sciences-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.