dc.contributor.advisorCagnon, José Ângelo [UNESP]-
dc.contributor.authorAndreoli, André Luiz-
dc.date.accessioned2014-06-11T19:24:06Z-
dc.date.accessioned2016-10-25T19:02:15Z-
dc.date.available2014-06-11T19:24:06Z-
dc.date.available2016-10-25T19:02:15Z-
dc.date.issued2005-08-12-
dc.identifier.citationANDREOLI, André Luiz. Controlador de demanda e fator de potência de baixo custo para unidades consumidoras de energia elétrica. 2005. 202 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Engenharia, 2005.-
dc.identifier.urihttp://hdl.handle.net/11449/89568-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/89568-
dc.description.abstractO presente trabalho é o resultado de uma pesquisa aplicada ao desenvolvimento de um equipamento eletrônico microprocessado destinado ao controle de demanda máxima e de fator de potência em instalações elétricas. Motivado pelo aumento na demanda e pela limitação nos recursos do sistema elétrico interligado, o uso de equipamentos que permitam o gerenciamento de energia pelo lado da demanda tem se difundido com grande velocidade, pois é o método de racionalização do uso de energia elétrica que apresenta boa relação entre custo e benefícios, trazendo resultados favoráveis em curto prazo. O uso de controladores de demanda máxima e de fator de potência nas instalações atendidas por contratos de fornecimento horo-sazonal é uma forma de garantir que o sistema não ultrapasse os limites contratuais, que resultam em aplicação de multa, e também um modo de se operar o sistema dentro de parâmetros conhecidos evitando perdas excessivas, racionalizando a utilização de seus componentes. Embora não exista regulamentação relacionada a tarifas diferenciadas de energia elétrica para unidades atendidas em baixa tensão, a utilização de controladores de demanda máxima e fator de potência pode trazer à esta classe de consumidores os benefícios do gerenciamento de energia, reduzindo perdas e em muitos casos permitindo a diminuição no valor da fatura de energia. Pelo ponto de vista do fornecimento, a existência de controle de demanda nas unidades consumidoras permite um melhor planejamento e maior aproveitamento do sistema de distribuição, minimizando investimentos no setor. Para aplicação em unidades consumidoras de porte reduzido, os equipamentos de gerenciamento de energia disponíveis no mercado apresentam dois inconvenientes principais: o excesso de recursos que na maioria dos casos não é explorado em sua...pt
dc.description.abstractThe present work is the result of an applied research to the development of an electronic microcontrolled device used in the control of maximum demand and power factor in small and medium range electric facilities. Stimulated by the increase of demand and limitation of electrical resources of the interconnected system, the use of demand-side energy management devices was increased, since this method is the better mode to provide the energy rationalization, good cost-benefits relationship and presents best results in a short time interval after its implementation. The use of maximum demand and power factor controllers in facilities with differential billing fares is a method of guarantee that the agreement limits will not be exceeded, resulting in penalties, and also a safe mode of system operation, reducing losses and rationalizing the use their components. Although don't exist regulation related to the differential billing applied to low-voltage supplied consumers, the use of maximum demand and power factor controllers can bring to this consumers category the benefits of energy management, reducing losses and in most cases decreasing the energy billing. In the supply point of view, the demand control in consumers units allow the better planning and the best utilization of distribution system, minimizing the investment in this sector. For application in small-size consumer units, the commercially available energy management devices have two inconvenient: excess of resources, in the most cases sub-utilized which increase the price, and the need of a special external energy meter or energy transducer, uncommon in this class of facility. The device developed in this research have an electronic energy measurement system and associated signals independent of the supplier's meter, and also... (Complete abstract click electronic access below)en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent202 f. : il.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectControle de processopt
dc.subjectSistema de energia elétrica - Controlept
dc.subjectEficiência energéticapt
dc.subjectGerenciamento de energiapt
dc.subjectEconomia de energiapt
dc.subjectDemand-side energy managementen
dc.subjectEnergy controlen
dc.subjectDirect load controlen
dc.subjectDemand controlen
dc.subjectPower factor controlen
dc.subjectEnergy efficiencyen
dc.subjectIndustrial controlen
dc.subjectEnergy savingen
dc.titleControlador de demanda e fator de potência de baixo custo para unidades consumidoras de energia elétricapt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileandreoli_al_me_bauru.pdf-
dc.identifier.aleph000331018-
dc.identifier.capes33004056080P8-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.