dc.contributor.authorBaldan, Carlos Alberto-
dc.contributor.authorLamas, Jerika Suely-
dc.contributor.authorShigue, Carlos Yujiro-
dc.contributor.authorRuppert Filho, Ernesto-
dc.date.accessioned2014-05-20T13:27:26Z-
dc.date.accessioned2016-10-25T16:47:20Z-
dc.date.available2014-05-20T13:27:26Z-
dc.date.available2016-10-25T16:47:20Z-
dc.date.issued2009-06-01-
dc.identifierhttp://dx.doi.org/10.1109/TASC.2009.2019043-
dc.identifier.citationIEEE Transactions on Applied Superconductivity. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 19, n. 3, p. 1810-1813, 2009.-
dc.identifier.issn1051-8223-
dc.identifier.urihttp://hdl.handle.net/11449/9013-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/9013-
dc.description.abstractA fault current limiter (FCL) based on an arrangement of parallel connected high temperature superconducting tapes constituting a limiter element was designed and tested in 220 V line for a fault current peak between 1 kA to 2 kA. The limiter employed second generation (2G) HTS tapes of YBCO coated conductor reinforced with stainless steel. Four tapes were electrically connected in parallel with 0.4 m effective length per element wherein 16 elements connected in series constitutes a single-phase unit. The FCL performance was evaluated through over-current and current fault tests. Its recovery characteristics were used to design the shunt protection. The designed limiting ratio is 4 for 16 elements and the experimental result for one element showed a 20% limiting ratio. For the fault current test one element can withstand five cycles of fault without degradation. It was observed recovery times below 0.5 s under nominal load using a shunt resistance of 173 m Omega.en
dc.description.sponsorshipCompanhia Paulista de Forca e Luz (CPFL)-
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent1810-1813-
dc.language.isoeng-
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)-
dc.sourceWeb of Science-
dc.subjectCurrent limiting ratioen
dc.subjectsuperconducting fault current limiteren
dc.subjectYBCO coated conductoren
dc.subjectYBCO recovery characteristicsen
dc.titleFault Current Limiter Using YBCO Coated Conductor-The Limiting Factor and Its Recovery Timeen
dc.typeoutro-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.description.affiliationUSP, EEL, Lorena, SP, Brazil-
dc.description.affiliationUniv Estadual Paulista, Dept Engn Eletr, Guaratingueta, SP, Brazil-
dc.description.affiliationUniv Estadual Campinas, Fac Engn Eletr & Comp, Campinas, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Dept Engn Eletr, Guaratingueta, SP, Brazil-
dc.identifier.doi10.1109/TASC.2009.2019043-
dc.identifier.wosWOS:000268282100169-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIEEE Transactions on Applied Superconductivity-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.