Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/9013
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Baldan, Carlos Alberto | - |
dc.contributor.author | Lamas, Jerika Suely | - |
dc.contributor.author | Shigue, Carlos Yujiro | - |
dc.contributor.author | Ruppert Filho, Ernesto | - |
dc.date.accessioned | 2014-05-20T13:27:26Z | - |
dc.date.accessioned | 2016-10-25T16:47:20Z | - |
dc.date.available | 2014-05-20T13:27:26Z | - |
dc.date.available | 2016-10-25T16:47:20Z | - |
dc.date.issued | 2009-06-01 | - |
dc.identifier | http://dx.doi.org/10.1109/TASC.2009.2019043 | - |
dc.identifier.citation | IEEE Transactions on Applied Superconductivity. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 19, n. 3, p. 1810-1813, 2009. | - |
dc.identifier.issn | 1051-8223 | - |
dc.identifier.uri | http://hdl.handle.net/11449/9013 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/9013 | - |
dc.description.abstract | A fault current limiter (FCL) based on an arrangement of parallel connected high temperature superconducting tapes constituting a limiter element was designed and tested in 220 V line for a fault current peak between 1 kA to 2 kA. The limiter employed second generation (2G) HTS tapes of YBCO coated conductor reinforced with stainless steel. Four tapes were electrically connected in parallel with 0.4 m effective length per element wherein 16 elements connected in series constitutes a single-phase unit. The FCL performance was evaluated through over-current and current fault tests. Its recovery characteristics were used to design the shunt protection. The designed limiting ratio is 4 for 16 elements and the experimental result for one element showed a 20% limiting ratio. For the fault current test one element can withstand five cycles of fault without degradation. It was observed recovery times below 0.5 s under nominal load using a shunt resistance of 173 m Omega. | en |
dc.description.sponsorship | Companhia Paulista de Forca e Luz (CPFL) | - |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | - |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
dc.format.extent | 1810-1813 | - |
dc.language.iso | eng | - |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | - |
dc.source | Web of Science | - |
dc.subject | Current limiting ratio | en |
dc.subject | superconducting fault current limiter | en |
dc.subject | YBCO coated conductor | en |
dc.subject | YBCO recovery characteristics | en |
dc.title | Fault Current Limiter Using YBCO Coated Conductor-The Limiting Factor and Its Recovery Time | en |
dc.type | outro | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | - |
dc.description.affiliation | USP, EEL, Lorena, SP, Brazil | - |
dc.description.affiliation | Univ Estadual Paulista, Dept Engn Eletr, Guaratingueta, SP, Brazil | - |
dc.description.affiliation | Univ Estadual Campinas, Fac Engn Eletr & Comp, Campinas, SP, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Dept Engn Eletr, Guaratingueta, SP, Brazil | - |
dc.identifier.doi | 10.1109/TASC.2009.2019043 | - |
dc.identifier.wos | WOS:000268282100169 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | IEEE Transactions on Applied Superconductivity | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.