Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/9017
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bianchi, Inacio | - |
dc.contributor.author | Magalhaes Filho, Paulo | - |
dc.contributor.author | Ferreira Sobrinho, Jose Pinto | - |
dc.date.accessioned | 2014-05-20T13:27:26Z | - |
dc.date.accessioned | 2016-10-25T16:47:20Z | - |
dc.date.available | 2014-05-20T13:27:26Z | - |
dc.date.available | 2016-10-25T16:47:20Z | - |
dc.date.issued | 2009-01-01 | - |
dc.identifier.citation | Xix Imeko World Congress: Fundamental and Applied Metrology, Proceedings. Budapest: Imeko, p. 730-732, 2009. | - |
dc.identifier.uri | http://hdl.handle.net/11449/9017 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/9017 | - |
dc.description.abstract | In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated. | en |
dc.format.extent | 730-732 | - |
dc.language.iso | eng | - |
dc.publisher | Imeko | - |
dc.source | Web of Science | - |
dc.subject | TRIAC-based fan speed control | en |
dc.subject | harmonics | en |
dc.subject | power efficiency | en |
dc.title | Power performance evaluation of an electric home fan with triac-based automatic speed control system | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | São Paulo State Univ, Dept Elect Engn, Guaratingueta, Brazil | - |
dc.description.affiliationUnesp | São Paulo State Univ, Dept Elect Engn, Guaratingueta, Brazil | - |
dc.identifier.wos | WOS:000275561600130 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Xix Imeko World Congress: Fundamental and Applied Metrology, Proceedings | - |