Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/9027
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sobrinho, P. M. | - |
dc.contributor.author | Magalhaes, P. | - |
dc.contributor.author | Carvalho, J. A. | - |
dc.date.accessioned | 2014-05-20T13:27:27Z | - |
dc.date.accessioned | 2016-10-25T16:47:23Z | - |
dc.date.available | 2014-05-20T13:27:27Z | - |
dc.date.available | 2016-10-25T16:47:23Z | - |
dc.date.issued | 2001-08-01 | - |
dc.identifier | http://dx.doi.org/10.1016/S0735-1933(01)00290-1 | - |
dc.identifier.citation | International Communications In Heat and Mass Transfer. Oxford: Pergamon-Elsevier B.V., v. 28, n. 6, p. 867-876, 2001. | - |
dc.identifier.issn | 0735-1933 | - |
dc.identifier.uri | http://hdl.handle.net/11449/9027 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/9027 | - |
dc.description.abstract | This study investigates the utilisation of a simplified model in the transient analysis of a thermal cooling process. In such process the external thermal resistance between the surface and the surroundings is high compared to the system internal thermal resistance, so that the first controls the heat transfer process. In this case the Biot number is lower than 0.1. Aluminium reels were utilised, which, with proper internal instrumentation, furnished experimental results for the thermal cooling process. Based on experimental data, a simplified model for the determination of the process film coefficient was used. Subsequently, experimental and theoretical results were compared. The change of the airflow direction was also investigated for the cooling process, aiming at process time optimisation. (C) 2001 Elsevier B.V. Ltd. | en |
dc.format.extent | 867-876 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.title | Time reduction in a forced-convection thermal process using simplified transient analysis | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Estadual Paulista, Dept Energia, BR-12516410 Guaratingueta, SP, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Dept Energia, BR-12516410 Guaratingueta, SP, Brazil | - |
dc.identifier.doi | 10.1016/S0735-1933(01)00290-1 | - |
dc.identifier.wos | WOS:000170850100014 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | International Communications In Heat and Mass Transfer | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.