Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/9037
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Camargo, JR | - |
dc.contributor.author | Ebinuma, C. D. | - |
dc.contributor.author | Silveira, J. L. | - |
dc.date.accessioned | 2014-05-20T13:27:28Z | - |
dc.date.accessioned | 2016-10-25T16:47:24Z | - |
dc.date.available | 2014-05-20T13:27:28Z | - |
dc.date.available | 2016-10-25T16:47:24Z | - |
dc.date.issued | 2005-11-01 | - |
dc.identifier | http://dx.doi.org/10.1016/j.ijrefrig.2004.12.011 | - |
dc.identifier.citation | International Journal of Refrigeration-revue Internationale Du Froid. Oxford: Elsevier B.V., v. 28, n. 7, p. 1124-1132, 2005. | - |
dc.identifier.issn | 0140-7007 | - |
dc.identifier.uri | http://hdl.handle.net/11449/9037 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/9037 | - |
dc.description.abstract | This paper presents the basic principles of the evaporative cooling process for human thermal comfort, the principles of operation for the direct evaporative cooling system and the mathematical development of the equations of thermal exchanges, allowing the determination of the effectiveness of saturation. It also presents the results of experimental tests in a direct evaporative cooler that take place in the Air Conditioning Laboratory at the University of Taubate Mechanical Engineering Department, and the experimental results are used to determinate the convective heat transfer co-efficient and to compare with the mathematical model. (c) 2005 Elsevier Ltd and IIR. All rights reserved. | en |
dc.format.extent | 1124-1132 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | Brazil | pt |
dc.subject | experiment | pt |
dc.subject | air conditioning | pt |
dc.subject | evaporative system | pt |
dc.title | Experimental performance of a direct evaporative cooler operating during summer in a Brazilian city | en |
dc.type | outro | - |
dc.contributor.institution | Univ Taubate | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Taubate, UNITAU, Dept Mech Engn, BR-12060440 Taubate, SP, Brazil | - |
dc.description.affiliation | São Paulo State Univ, UNESP, Dept Energy, BR-12516410 Guaratingueta, SP, Brazil | - |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Dept Energy, BR-12516410 Guaratingueta, SP, Brazil | - |
dc.identifier.doi | 10.1016/j.ijrefrig.2004.12.011 | - |
dc.identifier.wos | WOS:000232181800016 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | International Journal of Refrigeration-revue Internationale Du Froid | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.