Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/90798
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Souza, André Nunes de [UNESP] | - |
dc.contributor.author | Sant'Anna, Cezar José | - |
dc.date.accessioned | 2014-06-11T19:24:46Z | - |
dc.date.accessioned | 2016-10-25T19:04:51Z | - |
dc.date.available | 2014-06-11T19:24:46Z | - |
dc.date.available | 2016-10-25T19:04:51Z | - |
dc.date.issued | 2005-07 | - |
dc.identifier.citation | SANT'ANNA, Cezar José. Estudo do desempenho de sistemas de aterramento frente às descargas atmosféricas em instalações de baixa e média tensão. 2005. 95 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Engenharia, 2005. | - |
dc.identifier.uri | http://hdl.handle.net/11449/90798 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/90798 | - |
dc.description.abstract | O presente trabalho possui como linha mestra a apresentação de proposições técnicas para as instalações de baixa e média tensão na incidência de descargas atmosféricas, visando diminuir danos nos equipamentos elétricos dos consumidores. Para a realização dessas proposições foram estudados e analisados diversos casos relacionados ao sistema de aterramento recomendados pelas normas e publicações técnicas. A diretriz metodológica adotada nesta pesquisa incorporou estudos correlatos já consolidados, experimentos e também simulações computacionais. Os resultados obtidos foram analisados levando-se em conta a influência dos sistemas de aterramento e seus componentes, tais como: tipos de eletrodos, solo, tipo de condutor de descida e dispositivos de proteção contra surtos. | pt |
dc.description.abstract | The master line of this present study consists of the presentation of technical propositions related to low and medium tension installations in the incidence lightning, aiming to decrease damages on consumer's electrical equipment. For the accomplishment of those propositions, several cases related to the earthing systems recommended standards and publications have been studied and analyzed. The methodological directive adopted in the present research has been incorporated already consolidated correlate studies consolidated, experiments, as well as digital simulations. The results obtained have been analyzed taking into account the influence of the earthing systems and their components, such as: electrodes, soil, descending conductors and protection devices. | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
dc.format.extent | 95 f. : il. + anexo | - |
dc.language.iso | por | - |
dc.publisher | Universidade Estadual Paulista (UNESP) | - |
dc.source | Aleph | - |
dc.subject | Descargas eletricas | pt |
dc.subject | Descargas atmosféricas | pt |
dc.subject | Aterramento | pt |
dc.subject | Surto de tensões | pt |
dc.subject | Dispositivos de proteção contra surtos | pt |
dc.subject | Lightning | en |
dc.subject | Grounding | en |
dc.subject | Protection lightning | en |
dc.subject | Outbreak voltage | en |
dc.title | Estudo do desempenho de sistemas de aterramento frente às descargas atmosféricas em instalações de baixa e média tensão | pt |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | santanna_cj_me_bauru.pdf | - |
dc.identifier.aleph | 000391593 | - |
dc.identifier.capes | 33004056086P6 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.