DC FieldValueLanguage
dc.contributor.authorPaschoarelli, Luis Carlos-
dc.contributor.authorde Oliveira, Ana Beatriz-
dc.contributor.authorCote Gil Coury, Helenice Jane-
dc.date.accessioned2014-05-20T13:13:00Z-
dc.date.accessioned2016-10-25T16:33:38Z-
dc.date.available2014-05-20T13:13:00Z-
dc.date.available2016-10-25T16:33:38Z-
dc.date.issued2008-11-01-
dc.identifierhttp://dx.doi.org/10.1016/j.ergon.2008.01.013-
dc.identifier.citationInternational Journal of Industrial Ergonomics. Amsterdam: Elsevier B.V., v. 38, n. 11-12, p. 999-1006, 2008.-
dc.identifier.issn0169-8141-
dc.identifier.urihttp://hdl.handle.net/11449/915-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/915-
dc.description.abstractThis study presents procedures for assessing the redesign of ultrasound transducers. Wrist movements were recorded using elect rogoniometers. Perceptions of discomfort and acceptability of the new transducers were evaluated. The assessment was performed in two phases: (1) design of the product and an initial evaluation of movements during simulated activity with one mock-up and with two commercially available transducers; (2) project review and the development and evaluation of new mock-ups (2 and 3) by non-experienced subjects, and subjective assessment of all the mock-ups and commercial transducers by non-experienced subjects and trained physicians. First mock-up did not present improvements regarding the wrist movements and the time spent within safe amplitudes. The project review resulted in two new mock-ups that led to lower average amplitudes of movements (p <= 0,05) and more time spent within safe amplitudes. Thus, the application of quantitative (recording movements) and subjective (perceptions of discomfort and acceptability) approaches allowed for subsequent redesigns of the transducers that led to improvement of the product under evaluation.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent999-1006-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectUsabilityen
dc.subjectRedesignen
dc.subjectElectrogoniometryen
dc.subjectAcceptabilityen
dc.subjectDiscomforten
dc.subjectUltrasonographyen
dc.titleAssessment of the ergonomic design of diagnostic ultrasound transducers through wrist movements and subjective evaluationen
dc.typeoutro-
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniversidade Federal de São Carlos (UFSCar), Dept Phys Therapy, BR-13565905 São Carlos, SP, Brazil-
dc.description.affiliationSão Paulo State Univ, Fac Architecture Arts & Commun, Dept Ind Design, Bauru, SP, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Fac Architecture Arts & Commun, Dept Ind Design, Bauru, SP, Brazil-
dc.identifier.doi10.1016/j.ergon.2008.01.013-
dc.identifier.wosWOS:000261543600014-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Journal of Industrial Ergonomics-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp