Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/91720
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Padilha, Alcides [UNESP] | - |
dc.contributor.author | Souza, Luís Manoel de Paiva | - |
dc.date.accessioned | 2014-06-11T19:25:27Z | - |
dc.date.accessioned | 2016-10-25T19:06:51Z | - |
dc.date.available | 2014-06-11T19:25:27Z | - |
dc.date.available | 2016-10-25T19:06:51Z | - |
dc.date.issued | 2011-06-27 | - |
dc.identifier.citation | SOUZA, Luís Manoel de Paiva. Levantamento de coeficientes de desempenho de armazenador térmico associado a refrigerador doméstico modificado. 2011. 120 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Engenharia, 2011. | - |
dc.identifier.uri | http://hdl.handle.net/11449/91720 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/91720 | - |
dc.description.abstract | No estudo de reaproveitamento de energia térmica, os refrigeradores domésticos dissipam calor para o meio ambiente, através do seu condensador, e esse calor pode ser reciclado, ou seja, recuperado através de escoamento de água, como fluido refrigerante escoando pelo condensador e armazenada em um reservatório. Para isto, construi-se um aparato experimental contendo um refrigerador doméstico, duplex com capacidade de 263 litros para o gabinete de refrigeração e 74 litros para o gabinete de congelamento. O refrigerador tem seu condensador acrescido por um trocador de calor tipo tubos concêntricos em contra corrente, cuja fruição é condensar o fluido refrigente utilizando água em circulação. Dessa forma, caso ocorra o carregamento térmico total do tanque de armazenagem, o calor será originalmente dissipado para o meio ambiente, através do condensador aletado. A água aquecida é então armazenada em um reservatório térmico via estratificação térmica. Assim calculou-se as vazões de água aquecida e fluido refrigerante, como também o coeficiente de desempenho do sistema acumulado. Os resultados mostraram que a vazão de água bem como o coeficiente de desempenho do sistema aumenta de acordo com o aumento da pressão hidrostática. Desta maneira, dos resultados obtidos pode-se concluir que a otimização do experimento se dá de forma eficaz e que, o reaproveitamento da água quente proveniente do condensador é perfeitamente possível, reduzindoo consumo de energia elétrica com aquecedores de água e ainda, minimizando a dissipação de calor para o meio ambiente, sem alterar o funcionamento do refrigerador | pt |
dc.description.abstract | In the study of recycling thermal energy it is know that domestic refrigerators dissipate heat to environment through the condenser. This heat can be recycled by a water flow, as a coolant in a modified condenser, and stored in a Domestic Hot Water Storage Tanks (DHWST). Thereby, an experimental apparatus was built containing one domestic refrigerator, each one with capacity of 263 liters in the cooling cabinet and 74 liters in the freezing cabinet. The refrigerators had the condenser increase by a type heat exchanger concentric tubes with a counter-current flow, which has the function of replace the original finned exchanger, condensing the coolant with water flow. Thus, in case the total thermal loading of the storage tank, the heat is dissipated to the original environment through the condenser finned. The heated water is then stored in a thermal reservoir via thermal stratification. In these conditions, the flow of heated water and refrigerant was calculated, as well as the coefficient of performance of the system. The results show that the water flow rate and the coefficient of performance of the system increases with the increase in hydrostatic pressure. According to these results, the experiment optimization is effective and it is totally possible to reuse the warm from modified condenser system, what could reduce the electric energy consumption in water beater and minimize the heat dissipation to environment, without modifying the refrigerator operation | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
dc.format.extent | 120 f. : il. | - |
dc.language.iso | por | - |
dc.publisher | Universidade Estadual Paulista (UNESP) | - |
dc.source | Aleph | - |
dc.subject | Calor - Armazenamento | pt |
dc.subject | Refrigeração | pt |
dc.subject | Thermal energy | en |
dc.subject | Thermal storage | en |
dc.subject | Refrigeration system | en |
dc.title | Levantamento de coeficientes de desempenho de armazenador térmico associado a refrigerador doméstico modificado | pt |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | souza_lmp_me_bauru.pdf | - |
dc.identifier.aleph | 000675684 | - |
dc.identifier.capes | 33004056080P8 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.