You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/91996
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMoraes, João Carlos Silos [UNESP]-
dc.contributor.authorRocha, Renata Sanches Ferreira-
dc.date.accessioned2014-06-11T19:25:33Z-
dc.date.accessioned2016-10-25T19:07:25Z-
dc.date.available2014-06-11T19:25:33Z-
dc.date.available2016-10-25T19:07:25Z-
dc.date.issued2006-07-10-
dc.identifier.citationROCHA, Renata Sanches Ferreira. Estudo de propriedades físico-químicas de resinas odontológicas: grau de conversão, dureza e expansão térmica. 2006. 73 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Engenharia de Ilha Solteira, 2006.-
dc.identifier.urihttp://hdl.handle.net/11449/91996-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/91996-
dc.description.abstractAs resinas compostas vêm sendo estudadas de longa data, sempre na procura de propiciar aos clínicos um melhor entendimento do seu processo de polimerização e a obtenção de melhores resultados nos procedimentos restauradores. A proposta deste trabalho foi determinar o grau de conversão, a microdureza e o coeficiente de expansão térmica das resinas restauradoras TPH Spectrum (Dentsply) e Filtek P60 (3M), em função da profundidade. Os materiais foram polimerizados por uma fonte de luz halógena durante 40 segundos em anéis de alumínio em diferentes espessuras (1, 2, 3 e 4 mm). O grau de conversão foi determinado através da espectroscopia no infravermelho próximo com transformada de Fourier, utilizando a razão entre bandas de absorção correspondentes às ligações duplas alifáticas e aromáticas. Para tanto, foram confeccionadas pastilhas contendo 20mg de resina e 150mg de KBr e os espectros foram obtidos em um espectrômetro Nexus 670 (Nicolet). As medidas de microdureza Vickers foram obtidas com um aparelho HMV 2000 (Shimadzu), utilizando uma amostra de cada espessura. A expansão térmica foi estudada através da técnica da extensometria. Os resultados mostraram que para as duas resinas ocorre uma diminuição no grau de conversão e na microdureza à medida que se aumenta a profundidade, como esperado. Para as medidas de expansão térmica, a resina Filtek P60 não apresentou diferenças significativas nas quatro profundidades, enquanto para a resina TPH Spectrum houve um aumento no coeficiente de expansão térmica com a profundidade. Não foi observada uma correlação entre o grau de conversão e a microdureza nas duas resinas estudadas. A determinação do grau de conversão através de espectros de absorção no infravermelho próximo mostrou-se mais preciso do que quando determinado a partir de espectros na região infravermelho médio.pt
dc.description.abstractThe composite resins have been widely studied allowing a better understanding of the process of polymerization. As consequence, better results in the clinical procedures have been obtained. The purpose of this work was to study the degree of conversion, the hardness and the thermal expansion of the TPH Spectrum (Dentsply) and Filtek P60 (3M) resins in different depths. Samples were prepared for each resin using aluminum rings 10 mm in internal diameter and with different thickness (1, 2, 3, and 4 mm). Resin composites were cured with a halogen light curing unit for 40 s. The degree of conversion was determined from FTIR spectra by comparison of the aliphatic =CH2 bond at 4743 cm -1 with that of the aromatic component at 4623 cm -1 for the cured and uncured states. For that, pellets containing 20 mg of resin powder (cured or uncured) and 150 mg of KBr powder were made. The near infra-red spectra were obtained in a FT-IR spectrophotometer (model Nexus 670, Nicolet). The Vickers hardness was measured with a Micro Hardness Tester (model HMV 2000, Shimadzu). The thermal expansion was studied through the strain gauge technique. The results showed a decrease in the value of DC and hardness as increases the depth. For Filtek P60 resin, it was not observed significant difference in the coefficient of thermal expansion at different depths. On the other hand, an increase was observed in the coefficient as it increases the depth for the TPH Spectrum resin. There is not correlation between the conversion degree and the microhardness for the two studied resins. DC values more accurate were obtained from near infra-red spectra when compared with those obtained from medium infra-red spectra.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent73 f. : il.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectResinas dentariaspt
dc.subjectFourier, Espectroscopia de infravermelho por transformada dept
dc.subjectDilatação linearpt
dc.subjectDental resinsen
dc.subjectFourier transform infrared spectroscopyen
dc.subjectLinear dilatationen
dc.titleEstudo de propriedades físico-químicas de resinas odontológicas: grau de conversão, dureza e expansão térmicapt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filerocha_rsf_me_ilha.pdf-
dc.identifier.aleph000470393-
dc.identifier.capes33004099083P9-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.