You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/9383
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlves-Claro, A. P. R.-
dc.contributor.authorClaro, F. A. E.-
dc.contributor.authorUzumaki, E. T.-
dc.date.accessioned2014-05-20T13:28:14Z-
dc.date.accessioned2016-10-25T16:48:00Z-
dc.date.available2014-05-20T13:28:14Z-
dc.date.available2016-10-25T16:48:00Z-
dc.date.issued2008-10-01-
dc.identifierhttp://dx.doi.org/10.1007/s10856-008-3439-9-
dc.identifier.citationJournal of Materials Science-materials In Medicine. Dordrecht: Springer, v. 19, n. 10, p. 3273-3277, 2008.-
dc.identifier.issn0957-4530-
dc.identifier.urihttp://hdl.handle.net/11449/9383-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/9383-
dc.description.abstractObjectives The purpose of this work was to submit the Nitinol files to plasma immersion ion implantation (PIII) and evaluate the effects of the surface treatment. Materials and Methods Wear resistance was determined in vitro by using an equipment for the application of horizontal movements on previously prepared notched plates made of resin. Vickers microhardness was measured in plates and files, before and after surface treatment and the surface chemical composition of the instruments was determined by X-rays photoelectron spectroscopy. Results The hardness values found for the treated Nitinol files were significantly lower than the hardness values measured before the implantation process. The comparison of commercially available instruments shows that the wear resistance of the stainless steel file is higher than the resistance of the Nitinol. Conclusions The results found led to the conclusion that the surface treatment significantly increased the Nitinol files wear resistance.en
dc.format.extent3273-3277-
dc.language.isoeng-
dc.publisherSpringer-
dc.sourceWeb of Science-
dc.titleWear resistance of nickel-titanium endodontic files after surface treatmenten
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.description.affiliationSão Paulo State Univ, Mat & Technol Dept, Guaratingueta, SP, Brazil-
dc.description.affiliationUniv Estadual Campinas, Fac Mech Engn, Dept Mat, Campinas, SP, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Mat & Technol Dept, Guaratingueta, SP, Brazil-
dc.identifier.doi10.1007/s10856-008-3439-9-
dc.identifier.wosWOS:000258656600015-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Materials Science: Materials in Medicine-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.