Low voltage and variable-pressure scanning electron microscopy of fractured composites
Autor(es): 
Instituição: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0968-4328
Financiador: 
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo: 
Uncoated fracture surfaces of carbon-epoxy composites are investigated using a variable-pressure environmental scanning electron microscope (VP-ESEM), under optimized conditions for topographic description, image quality and sample preservation. Always using freeware or open source programs, parameters for low-voltage and low vacuum are stipulated with the support of Monte Carlo simulations combined to topographic measurements, tailoring the VP-ESEM setup for visualization of fine relief details. Based on topographic information from atomic force microscope (AFM) images, finest fracture steps were measured. These were the references to optimize and define boundaries for applied beam voltages and chamber pressures, restricted by the beam penetration depth and gas-electron interactions, guided by Monte Carlo simulations and signal-to-noise measurements. For VP mode, ideal chamber pressure was found around 30-40 Pa at 3 keV beam voltage and 6 mm working distance. Lower pressures will cause noise due to electron charging and gas excess provokes resolution degradation and noise due to positive charging and electron beam scattering, raising the skirt radius. When a larger working distance is necessary, it can be compensated by adjusting the detector bias and the probe current, or even lowering chamber pressure, but the signal-to-noise ratio will certainly change. Monte Carlo simulations provided a good approach to optimize imaging conditions under low vacuum and low voltage for fractographic analysis of carbon-epoxy composites. (C) 2012 Elsevier Ltd. All rights reserved.
Data de publicação: 
1-Out-2012
Citação: 
Micron. Oxford: Pergamon-Elsevier B.V. Ltd, v. 43, n. 10, p. 1039-1049, 2012.
Duração: 
1039-1049
Publicador: 
Pergamon-Elsevier B.V. Ltd
Palavras-chaves: 
  • Monte Carlo
  • Low voltage
  • Variable pressure scanning electron microscope
  • Signal-to-noise ratio
Fonte: 
http://dx.doi.org/10.1016/j.micron.2012.04.012
Endereço permanente: 
Direitos de acesso: 
Acesso restrito
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/9399
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.