You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/94385
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAcciari, Heloisa Andréa [UNESP]-
dc.contributor.advisorCodaro, Eduardo Noberto [UNESP]-
dc.contributor.authorTorres, Dimas Luiz-
dc.date.accessioned2014-06-11T19:27:10Z-
dc.date.accessioned2016-10-25T19:12:32Z-
dc.date.available2014-06-11T19:27:10Z-
dc.date.available2016-10-25T19:12:32Z-
dc.date.issued2013-08-02-
dc.identifier.citationTORRES, Dimas Luiz. Caracterização eletroquímica de filmes anódicos de titânio grau 2 visando aplicações biomédicas. 2013. 78 f. Dissertação (mestrado) – Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Engenharia de Guaratinguetá, 2013.-
dc.identifier.urihttp://hdl.handle.net/11449/94385-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/94385-
dc.description.abstractDiferentes tiposde tratamentos com titânio têm sido propostos com a finalidade de promover o desempenho biológico dos implantes por tornar a superfície bioativa. Muitos metais quando expostos à atmosfera sofrem um processo deoxidação que conduz à formação de uma fina camada de óxidos sobre a sua superfície. Estes produtos da reação podem proteger o metal de posterior corrosão. O processo eletroquímico de anodização de metais permite a obtenção de uma camada de óxido relativamente fina e mais densa que aquela formada naturalmente na atmosfera. No caso do titânio, esta camada tem sido utilizada para favorecer a nucleação de apatitas e, por conseguinte, a osseo integração. Neste estudo foi investigada a influência da concentração do eletrólito e do tempo de anodização na morfologia e no comportamento eletroquímico de filmes anódicos formados sobre titânio comercialmente puro. Métodos eletroquímicos e de análise de superfície foram usados para caracterizar as superfícies modificadas de titânio. Verificou-se que, tanto a concentração doeletrólito como o tempo de anodização afetam o crescimento e as características protetoras dos filmes em um meio que simula o soro fisiológico. Nos perfis potencio dinâmicos, observou-se que os valores dos potenciais de rompimento de filme passivo são afetados pelo tempo de anodização. Variações nos espectros de impedância foram associadas com um aumento no número de defeitos destes filmes-
dc.description.abstractDifferent types of treatments have been proposed with titanium in order to promote the biological performance of implants for making bioactive surface. Many metals when exposed to the atmosphere undergo an oxidation process leading to the formation of a thin oxide layer on its surface. These reaction products can protect the metal from corrosion. The electrochemical process anodizing allows metals to obtain a relatively thin oxide layer and more to denser than formed naturally in the atmosphere. In the case of titanium, this layer has been used to promote nucleation of apatite, and therefore the osseointegração. In this study, it was investigated the influence of electrolyte concentration and the anodizing time on the morphology and electrochemical behavior of anodic films formed on commercially pure titanium. Electrochemical method sand surface analysis were used to characterize the surface modification of titanium. It was found that both the concentration of the electrolyte as anodizing time, affect the growth and protective characteristics of the films in a medium that simulates the physiological serum. In potentiodynamic profiles, it was observed that the values of the potential disruption of the passive film are affected by the time of anodizing. Variations in the impedance spectra were associated with an increase in the number of defects of the filmsen
dc.format.extent78 f. il.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectMateriais biomédicospt
dc.subjectDióxido de titâniopt
dc.subjectEletroquimicapt
dc.subjectTitaniopt
dc.subjectFilmes metalicospt
dc.subjectMicroscopia eletronica de varredurapt
dc.subjectMetais - Oxidação anodicapt
dc.subjectMetalografiapt
dc.subjectBiomedical materialspt
dc.titleCaracterização eletroquímica de filmes anódicos de titânio grau 2 visando aplicações biomédicaspt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filetorres_dl_me_guara.pdf-
dc.identifier.aleph000719220-
dc.identifier.capes33004080027P6-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 