You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/96194
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorRached, Ricardo Samih Georges Abi [UNESP]-
dc.contributor.advisorVaz, Luis Geraldo [UNESP]-
dc.contributor.authorFernandes Filho, Romeu Belon-
dc.date.accessioned2014-06-11T19:28:02Z-
dc.date.accessioned2016-10-25T19:16:26Z-
dc.date.available2014-06-11T19:28:02Z-
dc.date.available2016-10-25T19:16:26Z-
dc.date.issued2008-04-01-
dc.identifier.citationFERNANDES FILHO, Romeu Belon. Avaliação da rugosidade, corrosão e aderência bacteriana no titânio comercialmente puro após ação de fluoretos em diferentes períodos. 2008. 90 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Odontologia de Araraquara, 2008.-
dc.identifier.urihttp://hdl.handle.net/11449/96194-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/96194-
dc.description.abstractO objetivo deste estudo foi avaliar a rugosidade superficial e o processo de corrosão do titânio comercialmente puro (Ti cp), após simular períodos de contato com fluoretos de 5 (G5), 10 (G10), 15 (G15) e 20 (G20) anos, bem como avaliar a aderência de S. mutans nestas superfícies. Para cada respectivo período, discos de Ti cp foram previamente polidos e então imersos em solução fluoretada a 0,15% (1500 ppm, pH 5,3) ou em água destilada como controle (G0). A rugosidade média (Ra), rugosidade média quadrática (Rms) e a área superficial projetada (Área) foram avaliadas por microscopia de força atômica (MFA) antes e após a imersão. As mesmas superfícies foram examinadas por microscopia eletrônica de varredura (MEV e EDX) e a aderência dos S. mutans avaliada pela contagem das unidades formadoras de colônia (UFC/ml). Todos os grupos teste aumentaram significativamente a Ra, Rms e Área após a imersão em solução fluoretada. Entretanto, na comparação entre os grupos (Kruskall- Wallis), somente a Área foi estatisticamente diferente. Os grupos G10 (p=0,008), G15 (p=0,014) e G20 (p<0,001) apresentaram maior Área quando comparados com G0. A análise por MEV mostrou a presença de corrosão por pits e uma superfície irregular em todos os grupos teste. O G0 não sofreu alteração em nenhum parâmetro avaliado. O EDX mostrou a presença de compostos de Ti-FNa incorporados à superfície do G20. Na contagem das UFC/ml, o grupo G20 apresentou maior aderência que G0 e G5. Conclui-se que os íons fluoretos em baixa concentração foram capazes de promover corrosão do Ti cp em todos os grupos teste e alteraram a Área do Ti cp ao longo do tempo. Adicionalmente, a aderência bacteriana mostrou-se maior no período mais longo de exposição.pt
dc.description.abstractThe aim of this study was to evaluate the superficial roughness and the corrosion process of commercially pure titanium Ti cp, after simulating different periods of fluoride contact: 5 (G5), 10 (G10), 15 (G15) e 20 (G20) years, as well as the adherence of S mutans in those surfaces. For each respective period, Ti cp discs were previously polished and than submersed in fluoride solution 0.15% (1500 ppm, pH 5.3) or distilled water as control group (G0). The average roughness (Ra), root mean square roughness (Rms) and scanned area (Area) were assessed for atomic force microscopy (AFM) before and after the immersion. The same surfaces were examined for scanned electron microscopy (SEM, EDX) and S mutans adherence calculated by the counting of colony forming units (CFU/ml). All test groups increased significantly the Ra, Rms and Area after the immersion in fluoride solution. However, the comparison among the groups (Kruskall-Wallis), only the area showed significant difference. The groups G10 (p=0.008), G15 (p=0.014) and G20 (p<0.001) showed higher Area compared with G0. The SEM analysis showed the presence of corrosion by pits and irregular surface in all test groups. The G0 did not change for any parameter evaluated. The EDX showed the presence of Ti-F-Na in the surface of samples from G20. In the counting of CFU/ml, the G20 resulted in higher bacteria adherence compared with G0 and G5 (ANOVA, p=0.015). In conclusion the fluoride ions in low concentration promoted corrosion in Ti cp from all test groups and altered the Area of Ti cp over the time. Moreover, the longer is the period of immersion in fluoride solution, higher is the bacteria adherence.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent90 f. : il. color.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectTitaniopt
dc.subjectFluoretospt
dc.subjectCorrosãopt
dc.subjectAderência bacterianapt
dc.subjectMicroscopia de força atômicapt
dc.subjectMicroscopia eletronica de varredurapt
dc.subjectTitaniumen
dc.subjectFluorideen
dc.subjectCorrosionen
dc.subjectBacterial adherenceen
dc.subjectAtomic force microscopyen
dc.subjectScanned electron microscopyen
dc.titleAvaliação da rugosidade, corrosão e aderência bacteriana no titânio comercialmente puro após ação de fluoretos em diferentes períodospt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filefernandesfilho_rb_me_arafo.pdf-
dc.identifier.aleph000550702-
dc.identifier.capes33004030059P1-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.