You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/96204
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMarcantonio Junior, Elcio [UNESP]-
dc.contributor.advisorGuastaldi, Antonio Carlos [UNESP]-
dc.contributor.authorFaeda, Rafael Silveira-
dc.date.accessioned2014-06-11T19:28:03Z-
dc.date.accessioned2016-10-25T19:16:28Z-
dc.date.available2014-06-11T19:28:03Z-
dc.date.available2016-10-25T19:16:28Z-
dc.date.issued2006-03-16-
dc.identifier.citationFAEDA, Rafael Silveira. Avaliação de implantes de titânio com modificação da superfície por abrasão a laser ou recobrimento por hidroxiapatita biomimétrica. Estudo biomecânico em tíbia de coelhos. 2006. 110 p. Dissertação (mestrado) - Universidade Estadual Paulista - Faculdade de Odontologia, 2006.-
dc.identifier.urihttp://hdl.handle.net/11449/96204-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/96204-
dc.description.abstractO sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O propósito do presente estudo foi avaliar duas novas superfícies de implantes (modificada por laser - SML e recoberta por hidroxiapatita biomimética - HA), comparando-as a outros dois implantes comerciais, (superfície usinada - SU e modificada por jateamento e ataque ácido - SMC). Um total de 96 implantes (3,75 x 10mm), 24 de cada superfície, foram instalados na tíbia de coelhos e avaliados após 4, 8 e 12 semanas. Após os períodos de cicatrização os animais foram sacrificados, os implantes expostos e a força necessária para derosquea-los foi aferida por um torquímetro analógico. Em 4 e 8 semanas, os implantes HA apresentaram valor de torque de remoção estatisticamente superior (p<0,05) quando comparado aos demais, sendo o mesmo observado para os implantes SML quando comparados aos SU. Após 12 semanas, os implantes HA e SML foram estatisticamente superiores aos implantes SU. Os resultados deste estudo sugerem que os implantes HA foram superiores aos demais nos períodos iniciais, obtendo uma estabilidade satisfatória com 4 semanas de implantação. Os implantes SML foram superiores aos SU em todos os períodos avaliados, porém não apresentando diferenças quando com parados aos SMC.pt
dc.description.abstractThe success of modern dental implant systems has been associated with the development of implant designs and surface characteristic. The purpose of this study was to evaluate two new implant surfaces (laser-modified - LSM and biomimetic-hydroxyapatite coating - HA) comparing them with two other commercial implants (machined surface -MS and modified by sandblasted and acid etched - MCS). A total of 96 implants (3,75 x 10mm), 24 of each surface, were placed in rabbit tibia being evaluated after 4, 8 and 12 weeks. After the healing periods, the animals were sacrificed, the implants sites were exposed, and the needed force to unscrew the implants was measured using an analogical torque gauge. At 4 and 8 weeks, the HA implants removal torque was statistically greater (p<0,05) in comparison with the others, being the same observed to LSM when compared with MS. After 12 weeks, the HA and LSM implants were statistically greater just when compared with MS. The results of this study suggest that the HA implants were superior to the other at the initial periods, having a satisfactory stability with 4 weeks post-implantation. The LSM implants were superior to MS at all periods evaluated, but having no difference when compared with MCS.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipUniversidade Estadual Paulista (UNESP)-
dc.format.extent110 p. : il.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectImplante dentário endoósseopt
dc.subjectOsseointegraçãopt
dc.subjectLaser em Odontologiapt
dc.subjectMateriais biomédicospt
dc.subjectDental implantationen
dc.subjectEndosseousen
dc.subjectOsseointegrationen
dc.subjectTorqueen
dc.subjectLasersen
dc.subjectBiocompatible materialsen
dc.titleAvaliação de implantes de titânio com modificação da superfície por abrasão a laser ou recobrimento por hidroxiapatita biomimétrica. Estudo biomecânico em tíbia de coelhospt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filefaeda_rs_me_arafo.pdf-
dc.identifier.aleph000477186-
dc.identifier.capes33004030059P1-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.