Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/9687
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Milanez, Dalgerti L. | - |
dc.contributor.author | Ciric, Rade A. | - |
dc.date.accessioned | 2014-05-20T13:28:57Z | - |
dc.date.accessioned | 2016-10-25T16:48:26Z | - |
dc.date.available | 2014-05-20T13:28:57Z | - |
dc.date.available | 2016-10-25T16:48:26Z | - |
dc.date.issued | 2007-01-01 | - |
dc.identifier | http://dx.doi.org/10.1016/j.epsr.2006.02.001 | - |
dc.identifier.citation | Electric Power Systems Research. Lausanne: Elsevier B.V. Sa, v. 77, n. 1, p. 93-98, 2007. | - |
dc.identifier.issn | 0378-7796 | - |
dc.identifier.uri | http://hdl.handle.net/11449/9687 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/9687 | - |
dc.description.abstract | One of the important issues about using renewable energy is the integration of dispersed generation in the distribution networks. Previous experience has shown that the integration of dispersed generation can improve voltage profile in the network, decrease loss, etc. but can create safety and technical problems as well. This work report the application of the instantaneous space phasors and the instantaneous complex power in observing performances of the distribution networks with dispersed generators in steady state. New IEEE apparent power definition, the so-called Buchholz-Goodhue effective apparent power, as well as new proposed power quality (oscillation) index in the three-phase distribution systems with unbalanced loads and dispersed generators, are applied. Results obtained from several case studies using IEEE 34 nodes test network are presented and discussed. (C) 2006 Elsevier B.V. All rights reserved. | en |
dc.format.extent | 93-98 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | instantaneous space phasors | pt |
dc.subject | instantaneous complex power | pt |
dc.subject | Buchholz-Goodhue effective apparent power | pt |
dc.subject | power definitions | pt |
dc.subject | unbalance | pt |
dc.subject | dispersed generators | pt |
dc.title | A new method for real time computation of power quality indices based on instantaneous space phasors | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Univ W England | - |
dc.description.affiliation | UNESP, Dept Engn Eletr, BR-15385000 Ilha Solteira, SP, Brazil | - |
dc.description.affiliation | Univ W England, Sch Elect & Comp Engn, Bristol BS16 1QY, Avon, England | - |
dc.description.affiliationUnesp | UNESP, Dept Engn Eletr, BR-15385000 Ilha Solteira, SP, Brazil | - |
dc.identifier.doi | 10.1016/j.epsr.2006.02.001 | - |
dc.identifier.wos | WOS:000240907500010 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Electric Power Systems Research | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.