Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/97316
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Vergani, Carlos Eduardo [UNESP] | - |
dc.contributor.advisor | Spolidório, Denise Madalena Palomari [UNESP] | - |
dc.contributor.author | Silva, Mariana Montenegro | - |
dc.date.accessioned | 2014-06-11T19:28:56Z | - |
dc.date.accessioned | 2016-10-25T19:18:51Z | - |
dc.date.available | 2014-06-11T19:28:56Z | - |
dc.date.available | 2016-10-25T19:18:51Z | - |
dc.date.issued | 2005-02-17 | - |
dc.identifier.citation | SILVA, Mariana Montenegro. Efetividade da irradiação por microondas na desinfecção de próteses totais. 2005. 140 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Odontologia de Araraquara, 2005. | - |
dc.identifier.uri | http://hdl.handle.net/11449/97316 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/97316 | - |
dc.description.abstract | Este estudo teve por objetivo avaliar a efetividade da irradiação por microondas na esterilização de próteses totais. Para isso, oitenta próteses totais padronizadas foram confeccionadas e submetidas à esterilização com óxido de etileno. As próteses foram então individualmente inoculadas (107 ufc/mL) com meio de cultura de Tryptic Soy Broth (TSB) contendo um dos seguintes microrganismos: C.albicans, S. aureus, B. subtilis e P. aeruginosa. Após 48 horas de incubação a 37oC, 40 amostras foram imersas em 200 mL de água e irradiadas a 650 W por 6 minutos. Quarenta amostras não irradiadas foram utilizadas como controle. A seguir, 25 uL da suspensão resultante das diluições seriadas de 10-1 a 10-6, foram semeados em placas de Petri contendo os meios de cultura seletivos para cada microrganismo. Todas as placas foram incubadas a 37oC por 48 horas. Após a incubação, as colônias foram quantificadas em ufc/mL. Para verificação da efetividade exposição às microondas em longo prazo as amostras irradiadas foram imersas em meio de cultura e incubadas a 37oC por 7 dias. A esterilização foi obtida, após 48 horas, para as próteses contaminadas com C.albicans, S. aureus e B. subtilis. Um pequeno número de colônias foi observado em 2 placas de Petri para o microrganismo P. aeruginosa. Após 7 dias de incubação a 37oC houve crescimento microbiológico em 3 culturas de TSB, sendo 2 para P. aeruginosa e um para B. subtilis. Todas as próteses totais do grupo controle apresentaram crescimento microbiano nas placas de Petri, após 48 horas de incubação a 37oC. A irradiação por microondas por 6 minutos a 650 W provou ser um método rápido e efetivo para desinfecção das próteses totais contaminadas com P. aeruginosa e B. subtilis além, de promover a esterilização das inoculadas com C. albicans e S. aureus. | pt |
dc.description.abstract | The aim of this study was to evaluate the effectiveness of microwave irradiation on the sterilization of complete dentures contaminated with individual suspension of 3 bacterias (P. aeruginosa, S. aureus and B. subtilis) and one fungus (C. albicans). Eighty simulated maxillary complete dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated (107 cfu/mL) with Tryptic Soy Broth (TSB) media containing one of the tested microorganisms. After incubation at 37°C for 48 hours, forty dentures were immersed in 200 mL of distilled water and submitted to microwave irradiation at 650 W for 6 minutes. Forty non – irradiated dentures were used as positive controls. Using 0.9% sodium chlorine solution as diluent, tenfold serial dilutions 10-1 – 10-6 were plated onto 4 selective media appropriate for each organism: Manitol Salt Agar for S. aureus, Miller Hinton for P. aeruginosa, Sabourand Agar containing 5 μg/mL gentamicin for C.albicans, and Tryptic Soy Agar for B. subtilis. All plates were incubated at 37°C for 48 hours and colonies counts of each plate were quantified (cfu/mL). To verify the long - term effectiveness ofmicrowave sterilization, the TSB beakers with the microwave specimens were incubated at 37°C for 7 days. Data were statistically analyzed by Kruskal – Wallis’s test (α=0.05). Irradiated dentures showed consistent sterilization of S. aureus, B. subtilis and C. albicans after 48 hours. Compared to P. aeruginosa control, a very low number of colonies were detected only in two plates. Turbidity was observed in three broth beakers, two from P. aeruginosa and one from B. subtilis, after 7 days incubation at 37°C. All control dentures showed microbial...(Complete abstract, click electronic access below) | en |
dc.format.extent | 140 f. : il. color. | - |
dc.language.iso | por | - |
dc.publisher | Universidade Estadual Paulista (UNESP) | - |
dc.source | Aleph | - |
dc.subject | Prótese total | pt |
dc.subject | Prótese dentária - desinfecção | pt |
dc.subject | Complete dentures - disinfection | en |
dc.title | Efetividade da irradiação por microondas na desinfecção de próteses totais | pt |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | silva_mm_me_arafo.pdf | - |
dc.identifier.aleph | 000322479 | - |
dc.identifier.capes | 33004030082P3 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.