You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/9738
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlves, D. A.-
dc.contributor.authorda Silva, LCP-
dc.contributor.authorCastro, C. A.-
dc.contributor.authorda Costa, V. F.-
dc.date.accessioned2014-05-20T13:29:02Z-
dc.date.accessioned2016-10-25T16:48:30Z-
dc.date.available2014-05-20T13:29:02Z-
dc.date.available2016-10-25T16:48:30Z-
dc.date.issued2003-08-01-
dc.identifierhttp://dx.doi.org/10.1016/S0378-7796(03)00024-5-
dc.identifier.citationElectric Power Systems Research. Lausanne: Elsevier B.V. Sa, v. 66, n. 2, p. 105-113, 2003.-
dc.identifier.issn0378-7796-
dc.identifier.urihttp://hdl.handle.net/11449/9738-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/9738-
dc.description.abstractThe conventional Newton's method has been considered inadequate to obtain the maximum loading point (MLP) of power systems. It is due to the Jacobian matrix singularity at this point. However, the MLP can be efficiently computed through parameterization techniques of continuation methods. This paper presents and tests new parameterization schemes, namely the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, the reactive power at shunts (capacitor or reactor), the transmission lines power losses (real and reactive), and transmission lines power (real and reactive). Besides their clear physical meaning, which makes easier the development and application of continuation methods for power systems analysis, the main advantage of some of the proposed parameters is that its not necessary to change the parameter in the vicinity of the MLP. Studies on the new parameterization schemes performed on the IEEE 118 buses system show that the ill-conditioning problems at and near the MLP are eliminated. So, the characteristics of the conventional Newton's method are not only preserved but also improved. (C) 2003 Elsevier B.V. B.V. All rights reserved.en
dc.format.extent105-113-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectvoltage stabilitypt
dc.subjectcontinuation methodspt
dc.subjectpower flowpt
dc.subjectmaximum loadingpt
dc.subjectlossespt
dc.titleAlternative parameters for the continuation power flow methoden
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.description.affiliationUniv Estadual Paulista, Fac Elect Engn, Dept Elect Engn, BR-15385000 Ilha Solteira, SP, Brazil-
dc.description.affiliationUNICAMP, Sch Elect & Comp Engn, BR-13081970 Campinas, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Fac Elect Engn, Dept Elect Engn, BR-15385000 Ilha Solteira, SP, Brazil-
dc.identifier.doi10.1016/S0378-7796(03)00024-5-
dc.identifier.wosWOS:000183969900002-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectric Power Systems Research-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.