You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/9739
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMalange, FCV-
dc.contributor.authorAlves, D. A.-
dc.contributor.authorda Silva, LCP-
dc.contributor.authorCastro, C. A.-
dc.contributor.authorda Costa, GRM-
dc.date.accessioned2014-05-20T13:29:02Z-
dc.date.accessioned2016-10-25T16:48:30Z-
dc.date.available2014-05-20T13:29:02Z-
dc.date.available2016-10-25T16:48:30Z-
dc.date.issued2004-08-01-
dc.identifierhttp://dx.doi.org/10.1109/TPWRS.2003.821633-
dc.identifier.citationIEEE Transactions on Power Systems. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc., v. 19, n. 3, p. 1690-1692, 2004.-
dc.identifier.issn0885-8950-
dc.identifier.urihttp://hdl.handle.net/11449/9739-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/9739-
dc.description.abstractThis letter presents an alternative approach for reducing the total real power losses by using a continuation method. Results for two simple test systems and for the IEEE 57-bus system show that this procedure results in larger voltage stability margin. Besides, the reduction of real power losses obtained with this procedure leads to significant money savings and, simultaneously, to voltage profile improvement. Comparison between the solution of an optimal power flow and the proposed method shows that the latter can provide near optimal results and so, it can be a reasonable alternative to power system voltage stability enhancement.en
dc.format.extent1690-1692-
dc.language.isoeng-
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)-
dc.sourceWeb of Science-
dc.subjectcontinuation methodpt
dc.subjectvoltage stability marginpt
dc.titleReal power losses reduction and loading margin improvement via continuation methoden
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.description.affiliationPaulista State Univ, Dept Elect Engn, FEIS, UNESP, BR-15385000 São Paulo, Brazil-
dc.description.affiliationUniv Campinas, BR-13080970 Campinas, SP, Brazil-
dc.description.affiliationState Univ São Paulo, BR-12560970 Sao Carlos, SP, Brazil-
dc.description.affiliationUnespPaulista State Univ, Dept Elect Engn, FEIS, UNESP, BR-15385000 São Paulo, Brazil-
dc.description.affiliationUnespState Univ São Paulo, BR-12560970 Sao Carlos, SP, Brazil-
dc.identifier.doi10.1109/TPWRS.2003.821633-
dc.identifier.wosWOS:000222975800053-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIEEE Transactions on Power Systems-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.