Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/9739
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Malange, FCV | - |
dc.contributor.author | Alves, D. A. | - |
dc.contributor.author | da Silva, LCP | - |
dc.contributor.author | Castro, C. A. | - |
dc.contributor.author | da Costa, GRM | - |
dc.date.accessioned | 2014-05-20T13:29:02Z | - |
dc.date.accessioned | 2016-10-25T16:48:30Z | - |
dc.date.available | 2014-05-20T13:29:02Z | - |
dc.date.available | 2016-10-25T16:48:30Z | - |
dc.date.issued | 2004-08-01 | - |
dc.identifier | http://dx.doi.org/10.1109/TPWRS.2003.821633 | - |
dc.identifier.citation | IEEE Transactions on Power Systems. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc., v. 19, n. 3, p. 1690-1692, 2004. | - |
dc.identifier.issn | 0885-8950 | - |
dc.identifier.uri | http://hdl.handle.net/11449/9739 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/9739 | - |
dc.description.abstract | This letter presents an alternative approach for reducing the total real power losses by using a continuation method. Results for two simple test systems and for the IEEE 57-bus system show that this procedure results in larger voltage stability margin. Besides, the reduction of real power losses obtained with this procedure leads to significant money savings and, simultaneously, to voltage profile improvement. Comparison between the solution of an optimal power flow and the proposed method shows that the latter can provide near optimal results and so, it can be a reasonable alternative to power system voltage stability enhancement. | en |
dc.format.extent | 1690-1692 | - |
dc.language.iso | eng | - |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | - |
dc.source | Web of Science | - |
dc.subject | continuation method | pt |
dc.subject | voltage stability margin | pt |
dc.title | Real power losses reduction and loading margin improvement via continuation method | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | - |
dc.description.affiliation | Paulista State Univ, Dept Elect Engn, FEIS, UNESP, BR-15385000 São Paulo, Brazil | - |
dc.description.affiliation | Univ Campinas, BR-13080970 Campinas, SP, Brazil | - |
dc.description.affiliation | State Univ São Paulo, BR-12560970 Sao Carlos, SP, Brazil | - |
dc.description.affiliationUnesp | Paulista State Univ, Dept Elect Engn, FEIS, UNESP, BR-15385000 São Paulo, Brazil | - |
dc.description.affiliationUnesp | State Univ São Paulo, BR-12560970 Sao Carlos, SP, Brazil | - |
dc.identifier.doi | 10.1109/TPWRS.2003.821633 | - |
dc.identifier.wos | WOS:000222975800053 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | IEEE Transactions on Power Systems | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.