You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/97847
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorPezza, Leonardo [UNESP]-
dc.contributor.advisorPezza, Helena Redigolo [UNESP]-
dc.contributor.authorFernandes, Flávio Cesar Bedatty-
dc.date.accessioned2014-06-11T19:29:08Z-
dc.date.accessioned2016-10-25T19:20:00Z-
dc.date.available2014-06-11T19:29:08Z-
dc.date.available2016-10-25T19:20:00Z-
dc.date.issued2011-06-20-
dc.identifier.citationFERNANDES, Flávio Cesar Bedatty. Desenvolvimento de métodos limpos para screening e determinação de sulfonamidas em matrizes diversas. 2011. 117 f. Dissertação (mestrado) - Universidade Estadual Paulista, Instituto de Química, 2011.-
dc.identifier.urihttp://hdl.handle.net/11449/97847-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/97847-
dc.description.abstractNeste trabalho foram desenvolvidos dois métodos ambientalmente mais amigáveis para screening e determinação de sulfonamidas em matrizes diversas. O primeiro método desenvolvido foi o de análise por injeção em fluxo (FIA) com detecção espectrofotométrica, o qual se baseia na reação entre sulfonamidas e o reagente cromogênico p-dimetilaminobenzaldeído (p-DAB - 1,34 x 10-2 mol L-1 ou 0,2 % m/v) em meio ácido (HCl - 2,05 x 10-1 mol L-1) com adição de dodecil sulfato de sódio (SDS - 3,0 x 10-2 mol L-1), o que aumentou significativamente a sensibilidade da reação a qual produz um produto amarelo com λmáx = 465 nm. A configuração escolhida para o sistema FIA foi a de zonas coalescentes empregando um injetor comutador de três peças. Neste caso, são adicionados a reação, volumes fixos da solução contendo o analito e da solução contendo o reagente, sendo estes de 502 e 150 μL, respectivamente, transportados por uma solução carregadora de HCl 5,0 x 10-2 mol L-1 até a confluência. A faixa linear estudada variou entre 0,2 mg L-1 a 5,0 mg L-1 (0,2 - 5,0ppm). Os limites de detecção (LOD) e de quantificação (LOQ) calculados foram entre 0,040 - 0,050 mg L-1 e 0,130 - 0,160 mg L-1, respectivamente. A freqüência analítica obtida foi de 60 análises por hora. O segundo método desenvolvido foi o de espectroscopia de reflectância difusa utilizando spot test. O método é baseado na reação entre sulfonamidas e o reagente cromogênico p-dimetilaminocinamaldeído (2,4 x 10-3 mol L-1 ou 0,042 % m/v) em meio ácido (HCl - 2,0 x 10-2 mol L-1) e SDS (3,5 x 10-2 mol L-1), sobre a superfície de um papel de filtro, produzindo um complexo colorido (λmáx = 560 nm) estável. Para a reação apenas 20 μL de cada solução foi utilizada, sendo um procedimento limpo, pois gera pouco resíduo ao meio ambiente. A faixa linear de...pt
dc.description.abstractIn this work were developed two environmentally friendly analytical methods for screening and determination of sulfonamides in several matrices. The first method developed was flow injection analysis (FIA) using spectrophotometric determination, which is based on the reaction between sulfonamide and coupling reagent p-dimethylaminobenzaldehyde (1.34 x 10-2 mol L-1 or 0.2 % m/v) in acid medium (HCl - 2.05 x 10-1 mol L-1) with the addition of sodium dodecyl sulfate (SDS - 3.0 x 10-2 mol L-1) what significantly increased the sensitivity of the reaction which yield a yellow product with λmáx = 465 nm. Merging zone configuration employing a three-piece manual injector-commutator was chosen for system FIA. In this case, are added to the reaction, fixed volumes of solution containing the analyte and the solution containing the reagent, the latter being of 502 and 150 μL, respectively, loaded via the porter (5.0 x 10-2 mol L-1) until confluent point. The linear range was 0.2 mg L-1 a 5.0 mg L-1 (0.2 - 5.0 ppm). The limits of detection LOD) and quantification (LOQ) estimated were 0.040 - 0.050 mg L-1 and 0.130 - 0.160 mg L-1, respectively. The average sample rate of 60 determinations per hour. The second method developed was diffuse reflectance spectroscopy using spot test analysis. The method is based on the reaction between sulfonamides and coupling reagent p-dimethylaminocinnamaldeyde (2.4 x 10-3 mol L-1 or 0.042% m/v) in acid medium (HCl - 2.0 x 10-2 mol L-1) and SDS (3.5 x 10-2 mol L-1), on the surface of filter paper, yielding a stable colored product (λ = 560 nm). For the reaction only 20 μL of reagent was applied, it’s a clear procedure, yielding a little quantity of residues. The linear range was 1.0-10.0 mg L-1 (1 - 10 ppm). The limits of detection (LOD) and quantification (LOQ) estimated were 0.140 a 0.200 mg L-1 and... (Complete abstract click electronic access below)en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent117 f. : il.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectQuimica analiticapt
dc.subjectEspectofotometriapt
dc.subjectSulfonamidaspt
dc.subjectAnalytical chemistryen
dc.subjectSpectrophotometryen
dc.subjectSulfonamidesen
dc.titleDesenvolvimento de métodos limpos para screening e determinação de sulfonamidas em matrizes diversaspt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filefernandes_fcb_me_araiq.pdf-
dc.identifier.aleph000688514-
dc.identifier.capes33004030072P8-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.