DC Field | Value | Language |
---|---|---|
dc.contributor.author | Baptista, Fabricio Guimaraes | - |
dc.contributor.author | Vieira Filho, Jozué | - |
dc.date.accessioned | 2014-05-20T13:29:10Z | - |
dc.date.accessioned | 2016-10-25T16:48:36Z | - |
dc.date.available | 2014-05-20T13:29:10Z | - |
dc.date.available | 2016-10-25T16:48:36Z | - |
dc.date.issued | 2010-08-01 | - |
dc.identifier | http://dx.doi.org/10.1109/JSEN.2010.2044037 | - |
dc.identifier.citation | IEEE Sensors Journal. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 10, n. 8, p. 1297-1303, 2010. | - |
dc.identifier.issn | 1530-437X | - |
dc.identifier.uri | http://hdl.handle.net/11449/9807 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/9807 | - |
dc.description.abstract | Piezoelectric transducers of PZT (lead zirconate titanate) have been widely used in structural health monitoring (SHM) systems based on the electromechanical (E/M) impedance technique. In this technique, damages in the structure are identified by measuring the electrical impedance of the transducer in an appropriate frequency range. Usually, the selection of the correct frequency range to detect and evaluate damage is obtained by trial and error methods. In this paper, it is proposed a formal procedure to determine the frequency ranges in which the PZT transducers are more sensitive for damage detection. Tests were carried out on specimens with different sizes and there was a good match between the theoretical and practical results. | en |
dc.description.sponsorship | Financiadora de Estudos e Projetos (FINEP) | - |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | - |
dc.format.extent | 1297-1303 | - |
dc.language.iso | eng | - |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | - |
dc.source | Web of Science | - |
dc.subject | Frequency | en |
dc.subject | impedance | en |
dc.subject | lead zirconate titanate (PZT) ceramics | en |
dc.subject | structural engineering | en |
dc.title | Optimal Frequency Range Selection for PZT Transducers in Impedance-Based SHM Systems | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | São Paulo State Univ UNESP, Dept Elect Engn, BR-15385000 Ilha Solteira São Paulo, Brazil | - |
dc.description.affiliationUnesp | São Paulo State Univ UNESP, Dept Elect Engn, BR-15385000 Ilha Solteira São Paulo, Brazil | - |
dc.identifier.doi | 10.1109/JSEN.2010.2044037 | - |
dc.identifier.wos | WOS:000286313000002 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | IEEE Sensors Journal | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |