You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/9807
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBaptista, Fabricio Guimaraes-
dc.contributor.authorVieira Filho, Jozué-
dc.date.accessioned2014-05-20T13:29:10Z-
dc.date.accessioned2016-10-25T16:48:36Z-
dc.date.available2014-05-20T13:29:10Z-
dc.date.available2016-10-25T16:48:36Z-
dc.date.issued2010-08-01-
dc.identifierhttp://dx.doi.org/10.1109/JSEN.2010.2044037-
dc.identifier.citationIEEE Sensors Journal. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 10, n. 8, p. 1297-1303, 2010.-
dc.identifier.issn1530-437X-
dc.identifier.urihttp://hdl.handle.net/11449/9807-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/9807-
dc.description.abstractPiezoelectric transducers of PZT (lead zirconate titanate) have been widely used in structural health monitoring (SHM) systems based on the electromechanical (E/M) impedance technique. In this technique, damages in the structure are identified by measuring the electrical impedance of the transducer in an appropriate frequency range. Usually, the selection of the correct frequency range to detect and evaluate damage is obtained by trial and error methods. In this paper, it is proposed a formal procedure to determine the frequency ranges in which the PZT transducers are more sensitive for damage detection. Tests were carried out on specimens with different sizes and there was a good match between the theoretical and practical results.en
dc.description.sponsorshipFinanciadora de Estudos e Projetos (FINEP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent1297-1303-
dc.language.isoeng-
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)-
dc.sourceWeb of Science-
dc.subjectFrequencyen
dc.subjectimpedanceen
dc.subjectlead zirconate titanate (PZT) ceramicsen
dc.subjectstructural engineeringen
dc.titleOptimal Frequency Range Selection for PZT Transducers in Impedance-Based SHM Systemsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationSão Paulo State Univ UNESP, Dept Elect Engn, BR-15385000 Ilha Solteira São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ UNESP, Dept Elect Engn, BR-15385000 Ilha Solteira São Paulo, Brazil-
dc.identifier.doi10.1109/JSEN.2010.2044037-
dc.identifier.wosWOS:000286313000002-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIEEE Sensors Journal-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.