Utilize este identificador para citar ou criar um link para este item:
http://acervodigital.unesp.br/handle/11449/9848Registro de metadados completo
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.contributor.author | Colvara, Laurence Duarte | - |
| dc.date.accessioned | 2014-05-20T13:29:15Z | - |
| dc.date.accessioned | 2016-10-25T16:48:40Z | - |
| dc.date.available | 2014-05-20T13:29:15Z | - |
| dc.date.available | 2016-10-25T16:48:40Z | - |
| dc.date.issued | 2009-05-01 | - |
| dc.identifier | http://dx.doi.org/10.1016/j.ijepes.2008.10.002 | - |
| dc.identifier.citation | International Journal of Electrical Power & Energy Systems. Oxford: Elsevier B.V., v. 31, n. 4, p. 139-145, 2009. | - |
| dc.identifier.issn | 0142-0615 | - |
| dc.identifier.uri | http://hdl.handle.net/11449/9848 | - |
| dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/9848 | - |
| dc.description.abstract | The power system stability analysis is approached taking into explicit account the dynamic performance of generators internal voltages and control devices. The proposed method is not a direct method in the usual sense since conclusion for stability or instability is not exclusively based on energy function considerations but it is automatic since the conclusion is achieved without an analyst intervention. The stability test accounts for the nonconservative nature of the system with control devices such as the automatic voltage regulator (AVR) and automatic generation control (AGC) in contrast with the well-known direct methods. An energy function is derived for the system with machines forth-order model, AVR and AGC and it is used to start the analysis procedure and to point out criticalities. The conclusive analysis itself is made by means of a method based on the definition of a region surrounding the equilibrium point where the system net torque is equilibrium restorative. This region is named positive synchronization region (PSR). Since the definition of the PSR boundaries have no dependence on modelling approximation, the PSR test conduces to reliable results. (C) 2008 Elsevier Ltd. All rights reserved. | en |
| dc.format.extent | 139-145 | - |
| dc.language.iso | eng | - |
| dc.publisher | Elsevier B.V. | - |
| dc.source | Web of Science | - |
| dc.subject | Power system transient stability | en |
| dc.subject | Control devices | en |
| dc.subject | Energy function | en |
| dc.subject | Automatic method | en |
| dc.title | Stability analysis of power systems described with detailed models by automatic method | en |
| dc.type | outro | - |
| dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
| dc.description.affiliation | São Paulo State Univ, UNESP, Elect Engn Dept IIha Solteira, São Paulo, Brazil | - |
| dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Elect Engn Dept IIha Solteira, São Paulo, Brazil | - |
| dc.identifier.doi | 10.1016/j.ijepes.2008.10.002 | - |
| dc.identifier.wos | WOS:000266177300001 | - |
| dc.rights.accessRights | Acesso restrito | - |
| dc.relation.ispartof | International Journal of Electrical Power & Energy Systems | - |
| Aparece nas coleções: | Artigos, TCCs, Teses e Dissertações da Unesp | |
Não há nenhum arquivo associado com este item.
Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.
