Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/9937
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorCastro, Heryca O. S.-
dc.contributor.authorGasche, Jose Luiz-
dc.contributor.authorPrata, Alvaro T.-
dc.date.accessioned2014-05-20T13:29:27Z-
dc.date.accessioned2016-10-25T16:48:48Z-
dc.date.available2014-05-20T13:29:27Z-
dc.date.available2016-10-25T16:48:48Z-
dc.date.issued2009-05-01-
dc.identifierhttp://dx.doi.org/10.1016/j.ijrefrig.2008.09.001-
dc.identifier.citationInternational Journal of Refrigeration-revue Internationale Du Froid. Oxford: Elsevier B.V., v. 32, n. 3, p. 421-429, 2009.-
dc.identifier.issn0140-7007-
dc.identifier.urihttp://hdl.handle.net/11449/9937-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/9937-
dc.description.abstractThis paper presents an experimental investigation of the ester oil ISO VG10/refrigerant R134a mixture flashing flow in a 6.0 m long, 3.22 mm ID tube, which is one of the primary steps towards the construction of a methodology for the study of the lubrication and gas leakage in refrigeration compressors. The phase change starts with solubility reduction of the refrigerant in the oil as the pressure decreases due to the friction forces. in this flashing flow the foam pattern is observed at the end of the tube as vapor quality reaches high values, and this is a particular phenomenon of this kind of mixture flow. In order to study this pressure drop, an experimental apparatus was designed to allow the measurement of both pressure and temperature profiles along the tube as well as the visualization of the flow patterns. Pressure and temperature distribution along the flow were measured for saturation pressure ranging from 450 to 650 kPa, mass flux ranging from about 2000 to 3000 kg/(m(2)s), temperatures around 303 K, and inlet refrigerant concentration varying between 0.2 and 0.4 kg ref/kg mixt. An available correlation proposed to predict the frictional pressure drop for a mixture composed by the mineral oil SUNISO 1GS and refrigerant R12 flowing in small diameter tubes yielded large deviations in predicting the ester oil and refrigerant R134a mixture flow. A new correlation has been proposed that fitted the experimental data with rms deviations of 24%. (C) 2008 Elsevier Ltd and IIR. All rights reserved.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent421-429-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectRefrigeration systemen
dc.subjectMixtureen
dc.subjectR134aen
dc.subjectSynthetic oilen
dc.subjectTwo-phase flowen
dc.subjectTubeen
dc.subjectGeometryen
dc.subjectExperimenten
dc.subjectPressure dropen
dc.subjectCorrelationen
dc.titlePressure drop correlation for oil-refrigerant R134a mixture flashing flow in a small diameter tubeen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)-
dc.contributor.institutionUniv Rio Verde-
dc.description.affiliationSão Paulo State Univ, UNESP, Dept Mech Engn, BR-15385000 Ilha Solteira, SP, Brazil-
dc.description.affiliationUniversidade Federal de Santa Catarina (UFSC), Dept Mech Engn, BR-88040970 Florianopolis, SC, Brazil-
dc.description.affiliationUniv Rio Verde, Coll Engn, BR-75901970 Rio Verde, Go, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Dept Mech Engn, BR-15385000 Ilha Solteira, SP, Brazil-
dc.identifier.doi10.1016/j.ijrefrig.2008.09.001-
dc.identifier.wosWOS:000265204200006-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Journal of Refrigeration-revue Internationale Du Froid-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.