You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/99715
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorGrandini, Carlos Roberto [UNESP]-
dc.contributor.authorMartins Júnior, José Roberto Severino-
dc.date.accessioned2014-06-11T19:30:19Z-
dc.date.accessioned2016-10-25T19:23:59Z-
dc.date.available2014-06-11T19:30:19Z-
dc.date.available2016-10-25T19:23:59Z-
dc.date.issued2010-09-23-
dc.identifier.citationMARTINS JÚNIOR, José Roberto Severino. Efeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mo. 2010. 140 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Ciências, 2010.-
dc.identifier.urihttp://hdl.handle.net/11449/99715-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/99715-
dc.description.abstractDesde 1970, o titânio e algumas de suas ligas são vastamente usados na fabrição de próteses e dispositivos especiais nas áreas médica e odontológica devido às suas propriedades como baixos valores de módulo de elasticidade (Módulo de Young), resistência à corrosão e características de biocompatibilidade. A presença de elementos intersticiais (oxigênio, carbono, nitrogênio e hidrogênio) altera de maneira significativa as propriedades mecânicas da liga, principalmente suas propriedades elásticas, causando endurecimento ou fragilização da liga. As medidas de espectroscopia mecânica constituem uma ferramenta poderosa para o estudo da interação destes elementos substitucionais e intersticiais com a matriz metálica. O objetivo do trabalho foi prepararA LIGA Ti-15Mo por fusão a arco, e estudar a influência de tratamentos térmicos e do oxigênio presente em solução sólida, na estrutura, propriedades mecânicas, químicas, anelásticas e biocompatibilidade da liga. Os resultados de difração de raios X analisados pelo método de Rietveld permitiram quantificar as fases presentes na microestrutura, estando de acordo com as micrografias obtidas. Os resultados de dureza e módulo de elasticidade mostraram ser sensíveis à concentração de oxigênio e à microestrutura da liga. Nos ensaios de corrosão houve uma melhora significativa do potencial de corrosão após as dopagens com oxigênio. As medidas de espectroscopia mecânica apresentaram estruturas de relaxação e foram identificados os processos constituintes. Os ensaios de biocompatibilidade mostraram que a liga em questão pode ser considerada biocompatívelpt
dc.description.abstractSince 1970, titanium and some of its alloys have been widely used in the manufacture of special devices and prostheses in medical and dental areas due to properties which include low elasticity modulus values, corrosion resistance and characteristics of biocumpatibility. The presence of interstial elements (carbon, nitrogen, oxygen and hydrogen) significantly alters the alloy's mechanical properties, mainly its elastic properties, causing either a hardening or softening of the alloy. Mechanical spectroscopy measurements are a powerful tool to study the interaction of these substitutional and interstitial elements with a metallic matrix. The aim of this work was to prepare the Ti-15Mo alloy by arc-melting and study the influence of heat treatments and oxygen present in the solid solution of the structure, as well as the mechanical, chemical and anelastic properties, and biocompatibility of the alloys. The results of x-ray diffraction were analyzed by the Rietveld Method to allow the phases present in the microestructure to be quantified according to the obtained micrographies. The hardness and elasticity modulus results were sensitive to the oxygen concentration and the alloy microstructure. In corrosion tests there was a significant improvement of the corrosion potential after the oxygen dopyng. The mechanical spectroscopy measurements showed relaxation structures, and constituent relaxation processes were identified. The biocompatibility tests showed that the alloy in question can be considered biocompatibleen
dc.format.extent140 f. : il., tabs.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectLigas de titaniopt
dc.subjectMetais - Tratamento termicopt
dc.subjectOxigeniopt
dc.subjectRietveld, Metodo dept
dc.subjectCorrosãopt
dc.subjectBiocompatibilidadept
dc.subjectBiomateriaispt
dc.subjectBiomaterialsen
dc.subjectTitanium alloysen
dc.subjectHeat treatmenten
dc.subjectInterstitial oxygenen
dc.subjectAnelasticityen
dc.subjectRietveld methoden
dc.subjectCorrosionen
dc.subjectBiocompatibilityen
dc.titleEfeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mopt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filemartinsjunior_jrs_me_bauru.pdf-
dc.identifier.aleph000628676-
dc.identifier.capes33004056083P7-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.