You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/9980
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDias, N. L.-
dc.contributor.authordo Carmo, D. R.-
dc.date.accessioned2014-05-20T13:29:31Z-
dc.date.accessioned2016-10-25T16:48:52Z-
dc.date.available2014-05-20T13:29:31Z-
dc.date.available2016-10-25T16:48:52Z-
dc.date.issued2005-09-01-
dc.identifierhttp://dx.doi.org/10.1002/elan.200403252-
dc.identifier.citationElectroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 17, n. 17, p. 1540-1546, 2005.-
dc.identifier.issn1040-0397-
dc.identifier.urihttp://hdl.handle.net/11449/9980-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/9980-
dc.description.abstractThe accumulation voltammetry of mercury(II) was investigated at a carbon paste electrode chemically modified with silica gel functionalized with 2,5-dimercapto-1,3,4-thiadiazole (DTTPSG-CPE). The repetitive cyclic voltammogram of mercury(II) solution in the potential range -0.2 to +0.8 V (vs. Ag/AgCl), (0.02 mol L-1 KNO3; nu=20 mV s(-1)) show two peaks one at about 0.0 V and other at 0.31 V. However, the cathodic wave peak, around 0.0 V, is irregular and changes its form in each cycle. This peak at about 0.0 V is the reduction current for mercury(II) accumulated in the DTTPSG-CPE. The anodic wave peak at 0.31 V is well-defined and does not change during the cycles. The resultant material was characterized by cyclic and differential pulse anodic stripping voltammetry performed with the electrode in differents supporting electrolytes. The mercury response was evaluated with respect to pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. The precision for six determinations (n=6) of 0.05 and 0.20 mg (L)-(1) Hg(II) was 2.8 and 2.2% (relative standard deviation), respectively. The method was satisfactory and used to determine the concentration of mercury(II) in natural waters contaminated by this metal.en
dc.format.extent1540-1546-
dc.language.isoeng-
dc.publisherWiley-Blackwell-
dc.sourceWeb of Science-
dc.subjectsilicapt
dc.subjectcarbon paste electrodespt
dc.subjectvoltammetrypt
dc.subjectmercury preconcentrationpt
dc.titleStripping voltammetry of mercury(II) with a chemically modified carbon paste electrode containing silica gel functionalized with 2,5-dimercapto-1,3,4-thiadiazoleen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Paulista, UNESP, Dept Quim & Fis, BR-15385000 Ilha Solteira, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Dept Quim & Fis, BR-15385000 Ilha Solteira, SP, Brazil-
dc.identifier.doi10.1002/elan.200403252-
dc.identifier.wosWOS:000231935600007-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectroanalysis-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.