You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/16448
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRibeiro, Roberta Chuqui-
dc.contributor.authorGiampaolo, Eunice Teresinha-
dc.contributor.authorMachado, Ana Lucia-
dc.contributor.authorVergani, Carlos Eduardo-
dc.contributor.authorPavarina, Ana Claudia-
dc.date.accessioned2014-05-20T13:46:28Z-
dc.date.accessioned2016-10-25T17:00:11Z-
dc.date.available2014-05-20T13:46:28Z-
dc.date.available2016-10-25T17:00:11Z-
dc.date.issued2008-09-01-
dc.identifierhttp://dx.doi.org/10.1016/j.ijadhadh.2007.09.002-
dc.identifier.citationInternational Journal of Adhesion and Adhesives. Oxford: Elsevier B.V., v. 28, n. 6, p. 296-301, 2008.-
dc.identifier.issn0143-7496-
dc.identifier.urihttp://hdl.handle.net/11449/16448-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/16448-
dc.description.abstractDuring microwave disinfection, the dentures are exposed to water at high temperature and this may affect the bond between the denture teeth and the acrylic resin from which dentures are made. In this study, a shear test was used to evaluate the effect of microwave disinfection (650W/6 min) on the bond strength of two types of denture teeth to three acrylic resins, with different polymerization methods. The specimens were submitted to the shear tests (0.5 mm/min) after: immersion in water (37 degrees C) for 48 h or 8 days (controls); two or seven cycles of microwave disinfection (test groups). Data (MPa) were analyzed using three-way ANOVA and Tukey HSD test (alpha = 0.05). Microwave disinfection did not adversely affect the bond strength of all tested materials with the exception of QC-20 bonded to SR Vivodent PE, for which a significant reduction was recorded after seven cycles of irradiation. (C) 2007 Elsevier Ltd. All rights reserved.en
dc.format.extent296-301-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectinterfacesen
dc.subjectadhesion by chemical bondingen
dc.subjectfractureen
dc.subjectacrylic resinsen
dc.titleEffect of microwave disinfection on the bond strength of denture teeth to acrylic resinsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-13560190 São Paulo, Brazil-
dc.description.affiliationSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, Brazil-
dc.description.affiliationSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-14801290 São Paulo, Brazil-
dc.description.affiliationSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-14806590 São Paulo, Brazil-
dc.description.affiliationSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-14801130 São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-13560190 São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-14801290 São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-14806590 São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Dent Mat & Prosthodont, BR-14801130 São Paulo, Brazil-
dc.identifier.doi10.1016/j.ijadhadh.2007.09.002-
dc.identifier.wosWOS:000255602200004-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Journal of Adhesion and Adhesives-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.